Cobra CPI 875 Скачать руководство пользователя страница 5

Intro

Operation

Customer
Assistance

Warranty

Notes

Notice

Main Icons

Secondary Icons

Caution

Warning

Installation

Intro

Operation

Customer
Assistance

Warranty

Notes

Notice

Main Icons

Secondary Icons

Caution

Warning

Installation

5

4

Installation
Requirements

To check your inverter’s performance before installation:

1. Turn the inverter off (see page 11

for details). If the power source
is a DC power supply, switch it
off as well.

2. Connect cables to power input

terminals (see page 7 for details).

3. Connect cables to power source

(see page 7 for details).

4. Check to make sure all

connections are secure.

5. Turn the inverter on. If the

power source is a DC power
supply, switch it on first.

6. Plug in the test load.

The inverter should supply 
power to the load. If the inverter 
is not working properly, refer to
the troubleshooting guide on 
page 14 or power and protection
indicators section on page 12.

Installation Requirements

The inverter must be installed in an area that meets 
all of the following requirements:

A. Dry

Do not place in an area where water can drip 
or splash on the inverter.

B. Cool

Ambient air temperature should be between 30°F 
and 105°F (0°C and 40°C). The cooler the better.

C. Ventilate

Allow at least one inch (three cm) of clearance around
the inverter for proper airflow. Make sure that ventilation
openings on the ends of the unit are not obstructed.

D. Safe

Do not install the inverter in the same compartment 
as a battery or in any compartment that contains
flammable liquids such as gasoline.

E. Close to Battery

Install unit as close to battery as possible (without
being in the same compartment) to minimize the 
length of cable required to connect the inverter to 
the battery. It is better and cheaper to run longer 
AC wires than longer DC wires (cables).

CAUTION To avoid fire, do not cover or obstruct
ventilation openings. Do not install inverter in a zero-
clearance compartment. Overheating may result.

CAUTION The inverter must only be connected to
batteries with a nominal output voltage of 12 volts.
It will not work with a 6 volt battery, and will be
damaged if it is connected to a 16 volt battery.

WARNING This unit contains components which 
can produce arcs or sparks. To prevent fire or
explosion, do not install in compartments containing 
a battery or flammable materials, or in a location
which requires ignition protected equipment.

Intro

Operation

Customer
Assistance

Warranty

Notes

Notice

Secondary Icons

Caution

Warning

Installation

Installation

Quick Evaluation 
Before Installation

Intro

Operation

Customer
Assistance

Warranty

Notes

Notice

Main Icons

Secondary Icons

Caution

Warning

Installation

Introduction

Nothing 

Comes Close to a Cobra

®

On/Off Switch to Off

Connect Terminals

Connect Power Source

On/Off Switch to On

USB Connection

Intro

Operation

Customer
Assistance

Warranty

Notes

Notice

Secondary Icons

Caution

Warning

Installation

Intro

Operation

Customer
Assistance

Warranty

Notes

Notice

Main Icons

Secondary Icons

Caution

Warning

Installation

Intro

Operation

Customer
Assistance

Warranty

Notes

Notice

Main Icons

Secondary Icons

Caution

Warning

Installation

Connect Test  Load

Intro

Operation

Customer
Assistance

Warranty

Notes

Notice

Main Icons

Secondary Icons

Caution

Warning

Installation

10273_CPI875_PH2  7/10/07  6:04 PM  Page 4

Содержание CPI 875

Страница 1: ...e further assistance after reading this manual Cobra Electronics offers the following customer assistance services For Assistance in the U S A Automated Help Desk English only 24 hours a day 7 days a week 773 889 3087 phone Customer Assistance Operators English and Spanish 8 00 a m to 6 00 p m CT Monday through Friday except holidays 773 889 3087 phone Questions English and Spanish Faxes can be re...

Страница 2: ...erter is out of warranty a letter will automatically be sent informing you of the repair charge or replacement charge If you have any questions please call 773 889 3087 for assistance Maintenance and Product Service Intro Operation Customer Assistance Warranty Notes Notice Main Icons Secondary Icons Caution Warning Installation Customer Assistance Nothing Comes Close to a Cobra Cooling Fan A3 A2 P...

Страница 3: ...Statements specify conditions which could cause damage to the unit or other equipment WARNING Statements identify conditions that could result in personal injury or loss of life General Precautions 1 Never install the inverter in a boat s engine compartment where gas and battery fumes are present 2 Do not operate the inverter if it has been dropped or damaged in any way 3 Do not open the inverter ...

Страница 4: ... into the AC receptacle and produces a low voltage output If the label on the AC adapter or charger states that it produces a low voltage AC or DC output less than 30 volts the inverter will have no problem powering the adapter safely Cobra 800 Watt Output Waveform Some very sensitive electronic equipment may not operate satisfactory on square wave or modified sine wave The output waveform is refe...

Страница 5: ...l unit as close to battery as possible without being in the same compartment to minimize the length of cable required to connect the inverter to the battery It is better and cheaper to run longer AC wires than longer DC wires cables CAUTION To avoid fire do not cover or obstruct ventilation openings Do not install inverter in a zero clearance compartment Overheating may result CAUTION The inverter...

Страница 6: ...urn the On Off Switch on the inverter to the off position If the power source is a DC power supply switch it off as well 2 Connect cable to the Power Input Terminals on right side panel of the inverter The red terminal is positive and the black terminal is negative Insert the ends of the cables onto the terminals and tighten the screws to clamp the cables safely Mounting Connecting Cables Intro Op...

Страница 7: ...t the same time The inverter will be damaged if its output is connected to AC voltage from another source Damage can even occur if the inverter is switched off CAUTION Do not connect the inverter to an AC branch circuit that has high power consumption loads It will not operate electric heaters air conditioners stoves and other electrical appliances that consume more than 800 watts CAUTION Loose co...

Страница 8: ...Secondary Icons Caution Warning Installation Nothing Comes Close to a Cobra Power Consumption For each piece of equipment you will be operating from the inverter you must determine the battery s reserve capacity how long the battery can deliver a specific amount of current in automotive batteries usually 25 amperes or ampere hour capacity a measure of how many amperes a battery can deliver for a s...

Страница 9: ...e Main Icons Secondary Icons Caution Warning Installation Operation Operating Limits Power Output The inverter can deliver 800 watts for about 60 minutes The inverter must cool for 15 minutes before it can resume operation at 800 watts Note The wattage rating applies to resistive loads The inverter will operate most AC loads within its power rating Some induction motors used in freezers pumps and ...

Страница 10: ...ut should be above 12V To extend the life of the fan it will stop when there is no load The speed of the fan increases as the load increases The unit is completely insulated in input and output for added safety Problem Symptom Low output voltage No output voltage No output voltage after prolonged use No output voltage Protect indicator lighted No output voltage No output voltage Low battery alarm ...

Страница 11: ...d by accident 2 In the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs 3 If the serial number has been altered defaced or removed 4 If the owner of the product resides outside the U S A All implied warranties including warranties of merchantability and fitness for a particular purpose are limited in duration to the length of this warranty Cobra shall n...

Отзывы: