Removal and replacement of ADU modules
8-84
Chapter 8: Service & maintenance
98-133966-G1
3. Rotate the antenna pedestal so that the Azimuth DDM faces the
service hatch.
4. Press in and turn the elevation locking pin (if available) to locked
position.
5. Rotate the Polarisation Unit so that you can reach the BUC fan.
6. Disconnect the fan connector.
7. Remove the 2x4 mm Allen screws.
8. Remove the BUC fan.
8.5.13.2
Inserting a new BUC Fan
To insert a new BUC Fan follow the instructions above in reverse order.
8.5.14
Replacing the Block Up Converter (BUC)
Figure 8-113: Removing the BUC fan
Figure 8-114: Block Up Converter (BUC), location
Step 6
Step 7
SAILOR900TM.book Page 84 Monday, September 16, 2013 11:01 AM
Содержание Sailor 900 VSAT
Страница 2: ...98 138976 A Cover_SAILOR 900 VSAT System_407090B indd 2 15 04 2013 15 54 39 ...
Страница 16: ...Table of contents xiv 98 133966 G1 SAILOR900TM book Page xiv Monday September 16 2013 11 01 AM ...
Страница 28: ...List of tables xxvi 98 133966 G1 SAILOR900TM book Page xxvi Monday September 16 2013 11 01 AM ...
Страница 257: ...Appendices SAILOR900TM book Page 1 Monday September 16 2013 11 01 AM ...
Страница 258: ...SAILOR900TM book Page 2 Monday September 16 2013 11 01 AM ...
Страница 338: ...CE R TTE H 2 Appendix H Approvals 98 133966 G1 SAILOR900TM book Page 2 Monday September 16 2013 11 01 AM ...
Страница 340: ...Eutelsat S A H 4 Appendix H Approvals 98 133966 G1 SAILOR900TM book Page 4 Monday September 16 2013 11 01 AM ...
Страница 354: ...Index 10 Chapter Index 98 133966 G1 SAILOR900TM book Page 10 Monday September 16 2013 11 01 AM ...
Страница 355: ...98 138976 A Cover_SAILOR 900 VSAT System_407090B indd 3 15 04 2013 15 54 40 ...
Страница 356: ...98 133966 G1 www cobham com satcom 98 138976 A Cover_SAILOR 900 VSAT System_407090B indd 4 15 04 2013 15 54 40 ...