Troubleshooting guide
98-135323-H
Chapter 3: Service & maintenance
57
Troubleshooting guide
Problem
Symptom
Remedy
The SAILOR
6282 AIS
Transponder
will not turn
on.
Green LED on
SAILOR 6282 AIS
Transponder is
off.
If the power cable is connected directly to the
SAILOR 6282 AIS Transponder then check that
the white wire in the power cable is connected
to the black wire (-DC). If power to SAILOR
6282 AIS Transponder is connected via the
connection board then check the jumper W8 is
placed in position
AIS ON
.
No communi-
cation
No flashing
yellow or red LED
on AIS
transponder
Check if a valid MMSI has been entered.
Check if a Pilot Port has been set.
No GPS
No signal from
GPS. Position
requested.
Check the antenna cable to the GPS.
Missing MMSI
Alarm showing
Transceiver fail
When powering up the SAILOR 6282 AIS
Transponder for the first time after leaving the
factory there is no MMSI stored in the SAILOR
6282 AIS Transponder. Enter a valid MMSI to
operate the SAILOR 6282 AIS Transponder.
Wrong MMSI
If a wrong MMSI number has been entered and
stored, or if there is a requirement to change it,
contact your authorized dealer.
Содержание SAILOR 6280
Страница 1: ...SAILOR 6282 AIS Transponder SAILOR 6280 6281 AIS System User manual...
Страница 2: ......
Страница 12: ...Table of contents x 98 135323 H...
Страница 74: ...Service and repair 62 Chapter 3 Service maintenance 98 135323 H...
Страница 82: ...Sentences defined by Cobham SATCOM 70 Appendix B NMEA sentences 98 135323 H...
Страница 90: ...98 135323 H www cobhamsatcom com...