Chapter 3: Connect the system
Connect power
33
3333
Co
nn
ec
t th
e
sy
st
em
3.4 Connect power
3.4.1 Power source
• If you are connecting additional NMEA2000 equipment other than
SAILOR 6194 or SAILOR 6018 to the CAN bus, the power source for the
mini-C system must supply 15 VDC (nominal). To convert to 15 VDC
you may use e.g. a SAILOR 6090 Power Converter or a SAILOR 6081
PSU and Charger.
• The power source must be able to deliver sufficient power for the
system units. Refer to
3.4.2 Connect the power cables
3.4.2.1 SAILOR 3027
The SAILOR 3027 has one CAN connector, which is also used for power
input.
1. Connect the red wire to DC+ and the black wire to DC- in the power
supply.
2. Connect the shield of the CAN cable to chassis on the power supply,
which must be connected to ship ground. See
Note
If your power source is supplying more than 15 V, the system
is not protected against incorrect wiring.
Caution!
If your power source is a battery, you must configure an
under-voltage protection for the battery. The battery
may be damaged if the correct under-voltage protection
is not applied! For details, see
Содержание SAILOR 6120
Страница 1: ...SAILOR 6120 30 40 50 Installation manual...
Страница 2: ......
Страница 3: ...i SAILOR 6120 30 40 50 Installation manual Document number 98 154541 A Release date November 15 2017...
Страница 12: ...List of tables x...
Страница 31: ...Chapter 2 Install the system Install the SAILOR 3027 19 2222 Install the system Vertical pole Horizontal pole...
Страница 96: ...Chapter 5 Installation check and test 84 Test the system with SAILOR 6018...
Страница 116: ...98 154541 A www cobham com satcom...