Chapter 5: Installation check and test
Test the system
73
555
Install
ation che
ck
and
5.2 Test the system
5.2.1 Basic system verification
After powering the system, check
that the upper right corner of the
SAILOR 6018 display shows that the
system is logged in and ready for use.
The system is logged in and ready when there is a green check mark at the
satellite icon and the display shows the current position and the Ocean
Region to which the system is logged on.
If the system is not ready, the status field may show one of the following:
The SAILOR 3027 is logged out of
the Inmarsat C network, but is
synchronized with the satellite.
The SAILOR 3027 is not
synchronized with a satellite, but is
scanning for the best signal.
There is no connection between
the SAILOR 3027 and the SAILOR
6018.
Is the shield of the CAN cable connected
correctly to the ship ground (hull)?
Is the polarity of power connections
correct? Red wire = DC+, Black wire = DC-
Check item
Reference
OK
Table 16: Installation check list (Continued)