background image

98-159746-A03

www.cobham.com/satcom

How to install the cables on the ADU

System Configuration - Example

Power

Terminal

Antenna

Power

I/O

LAN

Service

Reset

Antenna

DC-Input 12-24 VDC; 14-5.5 A

SIM-Card

12-24 VDC

Below Deck Unit

Above Deck Unit

TT-4338A

TT-4352A

cable

- Installation on bigger vessels: RG214/U up to 100 m length

Connector type: TNC

- Installation in a mechanically protected environment and shorter distances: RG223/U up to 25 m length

Cable requirements:

*

WLAN

Wireless SIP Phones

Wired IP Handset

Notebook

Power

PoE adapter

SIP Phone

Recommended

*

For further information, download the installation manual 

at www.cobham.com/satcom, Cobham SYNC Partner Portal,

or from the distributor.

Any responsibility or liability for loss or damage in connection with the use of this product and the accompanying documentation is disclaimed by Thrane & Thrane A/S. The information in this manual is provided for information purposes only, is subject to change without notice and may contain errors or inaccuracies. Manuals issued 

by Thrane & Thrane A/S are periodically revised and updated. Anyone relying on this information should acquire the most current version e.g. from www.cobham.com/satcom, Cobham SYNC Partner Portal, or from the distributor. Thrane & Thrane A/S is not responsible for the content or accuracy of any translations or reproductions, 

in whole or in part, of this manual from any other source. In the event of any discrepancies, the English version shall be the governing text. Thrane & Thrane A/S is trading as Cobham SATCOM.
Copyright © 2018 Thrane & Thrane A/S. All rights reserved.

1. Pass the 

Coax cable and the Grounding wire through the Grommet

2. Connect the 

Coax cable to the connector on the ADU

3. Fasten the 

Ground cable on the Washer with the Crimp

4. Fasten the 

Grommet around the TNC Connector using the Dual wire clips

Grommet

Dual wire clips

Crimp

Grounding wire

TNC Connector

Washer

* Connector type: TNC

Cable requirements:

- Installation on bigger vessels: RG214/U up to 100 m length

- Installation in a mechanically protected environment and shorter distances: RG223/U up to 25 m length