Field replacement procedure –
Doc. No.: 97-177616-A
25.
Connect the cables:
a) 2x LNB cables (socket wrench 8mm, 1.0 Nm),
b) BUC cable (wrench, 2.0 Nm),
c) OMT cable (insert carefully as the PCB is very
fragile)
d) polarisation motor cable.
26.
Mount the feed horn, tighten to 40 Nm.
27.
Switch on the antenna at the ADU power on/off
switch at the antenna control module and check
that the antenna goes through the POST
(antenna can move freely).