background image

 

Page 6 of 10 

 

www.cobham.com/satcom

Spare Part Instruction – SAILOR 100, 800 & 900A/B PMM 
Document No.: 97-138940-D 
Revision: D 

Troubleshooting – Event List: 

When an event is registered the web interface shows an event icon “

” in the icon bar as long as 

the event is active, the ACU display also shows active events.  

To view the event list with active events click the event icon from the icon bar (

) at the top of the 

web interface or select “HELPDESK” and then “Event list” from the navigation pane on the left of the 
user interface. 

 

 
The Events List page then shows a list of active events and notifications including:  

 

The time and date of the first occurrence (Time UTC)  

 

The event code (ID) 

 

The severity of the event message (Severity)  

 

A description describing the event (Text) 

For  a  more  comprehensive  diagnosis  of  the  event  displayed  reference  the  error  and  event  codes 
document,  document  number:  97-139344-A.  Once  diagnosed  replace  the  defective  component  and 
run the Power On Self Test (POST) and verify the operation of the system. 

*Note:  Active events are cleared from the event list when the error is cleared. They are then moved 
to the notifications section and are displayed there with the severity, after 24 hours the notifications 
are then cleared or after the system is restarted.  

 

Содержание SAILOR 100 TV

Страница 1: ...smit signal is correctly aligned to prevent interference with the services on the opposite polarity The PMM drives a stepper motor on the back of the dish to rotate the polarization unit of the VSAT a...

Страница 2: ...ice LED would also be illuminated red All power LED s should remain green providing they are receiving voltage Troubleshooting Diagnostic LEDs on the ACU The ACU has 3 LEDs Power Logon and Fail Pass V...

Страница 3: ...Log into the Antenna Control Unit ACU 1 Connect a straight through Ethernet cable from the LAN port of your laptop to the LAN 3 port of the ACU 2 Open the Network and Sharing Center on your laptop an...

Страница 4: ...TCP IPv4 Option 5 The Select the Use the following IP address button and enter in an IP address of 192 168 0 2 and a Subnet Mask of 255 255 255 0 6 Now click the OK button on both the IP Protocol Vers...

Страница 5: ...Instruction SAILOR 100 800 900A B PMM Document No 97 138940 D Revision D 8 You ll now have access to the systems DASHBOARD 9 The following procedure will tell you how to access the events list and di...

Страница 6: ...t page then shows a list of active events and notifications including The time and date of the first occurrence Time UTC The event code ID The severity of the event message Severity A description desc...

Страница 7: ...to the antenna using the service switch located on the rear of the pedestal 4 Locate the PMM on the rear of the dish 5 Rotate the antenna dish to 90 degrees of elevation facing upwards 6 Press in and...

Страница 8: ...connector with the coloured wires polarization encoder to the plug marked ORE on the PMM 13 Connect the 6 pin connector with 4 white wires to the plug marked ZRM on the PMM 14 Connect the 6 pin connec...

Страница 9: ...d stop to end stop and then back to its zero reference point at which point the polarization motor module will be at the highest point with the LNB coax cables pointing left The TV antenna wont drive...

Страница 10: ...oting Self Test You can run a self test on the ACU and ADU of the antenna system 1 From the HELPDESK page click the Self test option 2 The system will now run the Self test 3 Ensure the test is comple...

Отзывы: