Table 2.  Environmental Qualification Form (continued) 

 
TYPE/MODEL/PART NO.;  Model 265-[   ] 

 

 

Conditions 

DO-160E 

Section/ 

Paragraph 

 

Description of Conducted Tests 

Fungus resistance 

13.0 

Equipment meets requirements of Category F.  

Salt spray 

14.0 

Equipment meets requirements of Category X.  

Magnetic effect 

15.0 

Equipment meets requirements of Class Z. 

Power input 

16.0 

Equipment meets requirements of Categories 
B and Z.. 

Voltage spike 

17.0 

Equipment meets requirements of Category A. 

Audio frequency conducted 
susceptibility 

18.0 

Equipment meets requirements of Category Z.  

Induced signal susceptibility 

19.0 

Equipment meets requirements of Category ZC. 

Radio frequency susceptibility 

20.0 

Equipment meets requirements of Categories  

WWR. 

Emission of radio frequency energy 

21.0 

Equipment meets requirements of Category H. 

Lightning induced transient 
susceptibility 

22.0 

Equipment meets requirements of Category B3F3X. 

Lightning direct effect 

23.0 

Equipment identified as Category X, no test required. 

Icing 

24.0 

Equipment meets requirements of Category A. 

Electrostatic Discharge 

25.0 

Equipment meets requirements of Category A. 

Fire, Flammability 

26.0 

No test conducted. Identified as Category X. 

Other tests:   

 

Acceptance tests in accordance with dB Systems acceptance test procedures 265-4 and performance tests in 
accordance with RTCA Document DO-214, Section 2.8 were conducted to verify complete and proper operation 
of the Model 265-[   ] qualification test unit.  

Remarks: 
 

 

Tests of DO-160D, Sections 4.0, 5.0, 10.0, 12.0, 15.0, 16.0, and 18.0 were conducted at dB Systems, Inc. 
in Redmond, Washington. 

 

Tests of DO-160D, Section 6.0 were conducted at  

 

Tests of DO-160D, sections 7.0 and 8.0 were conducted at Cascade Tech in Portland, Oregon. 

 

Tests of DO-160D, sections 17.0, 19.0, 20.0. 21.0, 22.0, and 25.0 were conducted CKC Labs in Redmond, 
Washington. 

 

Tests of DO-160D, section 24.0 were conducted at Smiths Aerospace in Grand Rapids, Michigan. 

 

Analysis of DO-160E to DO-160D confirms compliance with DO-160E. 

 

Analysis of ED56A to ED112 confirms compliance with ED112. 

 

 

These commodities, technology or software are controlled in accordance with the United States Export Administration Regulations, Export Classification
Control Number(ECCN) 7E994. When exporting, diversion contrary to U.S. law is prohibited.

Содержание 265-005

Страница 1: ...ructions for Continued Airworthiness For inquiries regarding the content and currency of this manual contact Wulfsberg Electronics Division 6400 Wilkinson Drive Prescott Arizona 86301 Telephone 928 75...

Страница 2: ...ton 2013 05 29 15 00 09 07 00 Barb Page 2013 05 2 9 15 55 34 07 00 Zack Pahlman 2013 05 30 17 24 44 07 00 These commodities technology or software are controlled in accordance with the United States E...

Страница 3: ...0 CALIBRATION AND MAINTENANCE PROCEDURES 5 Tables Table 1 P1 Connector Pinout 3 Table 2 Environmental Qualification Form 6 Figures Figure 1 Outline Drawing Model 265 005 Area Microphone Preamplifier 4...

Страница 4: ...fication No MODs exist for Model 265 005 These commodities technology or software are controlled in accordance with the United States Export Administration Regulations Export Classification Control Nu...

Страница 5: ...class of aircraft to determine that the aircraft installation conditions are within the TSO standards TSO articles must have separate approval for installation in an aircraft The article may be insta...

Страница 6: ...1 percent Acoustic Distortion THD N Less than 5 percent Microphone Output 0 5 VRMS into 600 ohms nominal 1 0VRMS into 600 max Power Supply 28VDC 30mA Operating Temperature From 55 C to 70 C Operating...

Страница 7: ...1 per MIL C 24308 The Model 265 005 amplifier s input and output wires should be placed no less than 12 inches away from any 400 Hz current carrying power lines or lines carrying audio frequency inte...

Страница 8: ...S25212 P1 D SUBMINIATURE CONNECTOR 9 PIN POSITRONIC PART NUMBER MD9P5R50T20 WITH JACK SCREWS MATES WITH RD9F10GE0 5 750 0 0 030 146 05 1 481 0 0 030 37 62 3 507 89 07 0 414 0 093 0 750 19 05 5 365 136...

Страница 9: ...ists and schematics are included in this manual for use during troubleshooting and repair 5 0 AIRWORTHINESS LIMITATIONS The Airworthiness Limitations section is FAA approved and specifies inspections...

Страница 10: ...000 ft Decompression tested to 55 000 ft Tested to 15 000 ft Equipment meets the requirements of Category A2 Temperature variation 5 0 Equipment meets requirements of Category B Humidity 6 0 Equipment...

Страница 11: ...cing 24 0 Equipment meets requirements of Category A Electrostatic Discharge 25 0 Equipment meets requirements of Category A Fire Flammability 26 0 No test conducted Identified as Category X Other tes...

Отзывы: