2
Setting Up Network Remote Control
2-24
BBG-1300-FR PRODUCT MANUAL
BBG-1300-OM (V1.0)
Setting/Configuring Miscellaneous BBG-1300 Functions
Numerous other BBG-1300-FR operating and monitoring functions are
available via front panel control and via DashBoard. This section describes
these attributes and their setup.
Beeper Mute
•
To temporarily mute the device alert beeper, select the
BBG-1300-FR main menu (by pressing soft key
L1
). From the
choices, using Navigate/Select knob select
Mute Beeper
. The device
beeper will be temporarily muted.
•
To persistently mute the device alert beeper, perform the following
steps to access the
MUTE
jumper and set to
Mute
position.
1.
Remove the front bezel as shown in Figure 2-5 on page 2-7.
2.
(See Figure 2-10.) With device on side such that front bezel interface
PCB is oriented as shown, move the jumper from the Default position to
the Mute position.
3.
Re-install the front bezel as shown in Figure 2-5 and associated steps.
Figure 2-10 Mute Jumper
To mute beeper, disconnect and
move jumper from right-most pin
pair to left-most pin pair
Electronic device or assembly is susceptible
to damage from an ESD event. Handle only
using appropriate ESD prevention practices.
Front bezel interface connector
Содержание BBG-1300-FR