ERROR CODE
Error Code
Description
Appearance
Trouble shooting
Er 00
CPU Error
When switch on
the machine
1.
Change U1 CPU
2.
PCB is out of service.
Er 01
Error while
up the
winding cord
1.
When switch on
the machine
2.
When play the
game
3.
Auto Demo
1.
Check if the up-stop SW is loose
?
2.
Check if up-stop SW is out of work
?
3.
Check if the air-plug of the gantry set
connects well
?
4.
PCB is fault.
Er 03
Error while
down the
winding cord
When auto demo
1.
Check if the string at the winding wheel is
smooth
?
2.
Check if up-stop SW is out of work
?
3.
Check if the air-plug of the gantry set
connects well
?
4.
PCB is fault.
Er 0E
SENSOR is
out of service
1.
Check whether sensitivity of sensor is too high?
Please adjust the sensitivity-VR to make sure the
LED of Sensor is in Dark
status.
2.
Check J5 sensor harness is connected well?
3.
Sensor is fault.
4.
PCB is fault
Er 05
Stop-Forward
SW or
Stop-back SW
Error
1. When switch on
the machine
2. When play the
game
3. Auto Demo
1.
Check if the stop-forward SW or stop-back SW is
out of work?
2.
Check if the air-plug of the gantry set connects
well?
3.
PCB is fault.
Er 06
Stop-Left SW
Error
1. When switch on
the machine
2. When play the
game
3. Auto Demo
1.
Check if the Stop-Left SW is out of work?
2.
Check if the air-plug of the gantry set connects
well?
3.
PCB is fault
Er 07
Coin1 Meter
disconnected
n
1.
Check if the J5 PIN connects well?
2.
Check if the Meter is out of work? Check if the
Pin connects well?
3.
PCB is fault.
Er 08
Coin2 Meter
disconnected
Er 09
Er 10
Prize Meter
disconnected
Er 22
Cabinet size
check Error
when power
on
1.
Check if the stop-front SW or stop-back SW is
out of work?
2.
Check if the air-plug of the gantry set connects
well?
3.
Check the J4 Pin on the board connect well?
4.
PCB is fault