Coalbrookdale MUCH WENLOCK Скачать руководство пользователя страница 4

the fan or overhead cooker hood, then add this 
compensatory area to that recommended for the 
appliances primary air needs, to form a permanent air
vent.

3. Ensure the wall location of the fan does not deprive 

the appliance of primary air.

In Fig. 1b and 2a the stove is installed in an existing
recess directly below the chimney flue. The exit end of
the flue pipe must extend a minimum of 150mm into the
overhanging brickwork. Any cavities or pockets above the
register plate should as far as possible be filled with the
flue pipe exit extended into the throat of the chimney.
If a flue liner or insulated chimney is used, the diameter
should not be less than 175mm and 150mm respectively.
Fig. 2b shows a back flue outlet into a chimney brickwork.
In Fig. 3 the stove is connected to an existing brick flue
with a length of flue pipe. Square bends and horizontal
runs must not be used and a cleaning door included at
every bend.
EXTENDED LENGTHS OF HORIZONTAL PIPEWORK
MUST BE AVOIDED AND ARE NOT RECOMMENDED,
AND SHALL NOT EXCEED 150mm.

NOTE:

WHATEVER METHOD OF INSTALLATION IS

UTILISED, AIR MUST NOT BE ALLOWED TO ENTER
THE CHIMNEY EXCEPT THROUGH THE STOVE AND
ALL JOINTS MUST BE AIR-TIGHT. IF THE CHIMNEY IS
UNLINED AND THERE IS ANY DOUBT ABOUT ITS
CONDITION, IT SHOULD BE LINED IN ACCORDANCE
WITH CURRENT BUILDING REGULATIONS.

PROVISION  MUST ALWAYS BE MADE FOR SWEEPING
THE CHIMNEY.
IMPORTANT: CEMENT PIPES AND FITTINGS MUST
NOT BE USED WITHIN 2m OF THE STOVE OUTLET
CHIMNEYS OF PLAIN PIPE ARE NOT RECOMMENDED
BUT CERTAIN PROPRIETARY MAKES OF INSULATED
CHIMNEY ARE SUITABLE.

Handle the firedoor with care to ensure the glass panel
remains intact.
The stove is delivered fully assembled but all fire cement
joints should be examined for soundness and if
necessary, re-sealed before installation.
After unpacking the stove, remove all packaged parts
from inside the stove and inspect the stove to ensure no
damage gas occurred during delivery.
If there is a problem, contact your local stockist.
Packaged parts contain a Flue Outlet Blanking Plate, Flue
Collar (for top or back outlet) and Operating Tool Support
Collar Cradle complete with two screws to secure the
Cradle to the bottom R.H. side of stove.
1. Plug any of the 1in. BSP boiler connections not 

required and fit half unions as required.

2. Position the stove in required position relative to 

chimney flue and on non-combustible hearth ensuring
there is sufficient room allowed on stove R.H. side to
enable operation of riddling tool.
Blank off and seal with cover plate, flue outlet not 
used.

3. Cut length of 150mm diameter pipe to suit chosen 

method of flue connection. Insert flue pipe spigot in 
stove outlet socket and caulk joint with soft rope and
cement.
Top Flue Outlet installations must incorporate an 
access door in the flue pipe near the surface of the 
stove for flue cleaning.

4. Connect flue pipe to chimney with selected method.
5. Making connections to the boiler with provision for 

draining at the lowest point, fill with water and test.
Make good any brickwork around the pipes.

6. Check that the bottomgrate reciprocates correctly and

that the front firebar is correctly located.

Check that the system is full of water and free from air
locks.
a. When lighting, open firedoor and place paper and 

sticks with a small quantity of fuel onto the 
bottomgrate, ignite paper and set the ashpit door 
spinwheel fully open and lock firedoor.
When established, balance the water system.

b. With the appliance under fire, check for soundness of

seals/joints and that the flue functions correctly in 
permitting all smoke and fumes to be vented through
the chimney.

4

FLUE LAYOUT

INSTALLATION

COMMISSIONING

Содержание MUCH WENLOCK

Страница 1: ...e that the necessary personal protective clothing is worn when handling where applicable the pertinent parts that contain any of the listed materials that could be interpreted as being injurious to health and safety see below for information Firebricks Fuel beds Artificial Fuels when handling use disposable gloves Fire Cement when handling use disposable gloves Glues and Sealants exercise caution ...

Страница 2: ... Regulations Section J 1 2 3 and requirements as outlined in BS 6461 Part 1 and BS 7566 Parts 1 to 4 should be observed The structural flue through the chimney should not be less than 175mm diameter Pargeted lined flues 230mm x 230mm must be in sound condition and any internal offsets should not be less than 60 to the horizontal Check that the flue exit is not obstructed or reduced in size IMPORTA...

Страница 3: ...Water Undertaking Regulations for the Electrical Equipment of Buildings published by the Institute of Electrical Engineers and any relevant requirement of the Local Authority The appliance can be installed in a non combustible recess in which the hearth must be level and together with the adjacent walls conform to the current Building Regulations See Figs 1b and 2a A rectangular recess is required...

Страница 4: ...amined for soundness and if necessary re sealed before installation After unpacking the stove remove all packaged parts from inside the stove and inspect the stove to ensure no damage gas occurred during delivery If there is a problem contact your local stockist Packaged parts contain a Flue Outlet Blanking Plate Flue Collar for top or back outlet and Operating Tool Support Collar Cradle complete ...

Страница 5: ... complete stove 184Kg Bottomgrate bars there are six grate bars of one type and seven of another The seven bar occupy the ends and intermediate positions The six bars fit between these See that they are properly placed on the cross front firebar and move freely when riddled Flue Pipes C I Pipes and bends of 150mm diameter painted black are available through your local stockist Replacement parts if...

Страница 6: ...6 ...

Страница 7: ...7 ...

Страница 8: ... product improvement the Company reserves the right to change specifications and make modifications to the appliance described and illustrated at any time Manufactured By Aga Rayburn Station Road Ketley Telford Shropshire TF1 5AQ England www aga rayburn co uk www agacookshop co uk www agalinks com www cookcraft com ...

Отзывы: