1. SAFETY PRECAUTIONS 

 

 

1

 / 

12

 

 

 

 

Be sure to read the instructions in this section carefully before use. 
Make sure to observe the instructions in this manual as the conventions of safety symbols and messages 
regarded as very important precautions are included. 
We also recommend you keep this instruction manual handy for future reference. 

 

Safety  Symbol  and Message  Conventions 

Safety symbols and messages described below are used in this manual to prevent bodil y injury and property 
damage which could result from mishandling. Before operating your product, read this manual first and 
understand the safety symbols and messages so you are thoroughly aware of the potential safety 

 
 
 

Indicates a potentially hazardous situation which, if mishandled, could 
result in death or serious personal injury. 

 

Indicates a potentially hazardous situation which, if mishandled, could 
result in moderate or minor personal injury, and/or property damage. 

 

 
 
 
 
 
 
 

When  Installing the  Unit  

When  Installing the  Unit

 

 

Do not expose the unit to rain or an environment 

where  it may be splashed  by water or other liquids, 

as doing so may result in fire or electric shock.

 

 

Use the unit only with the voltage  specified on 
the  unit.  Using  a  voltage  higher  than  that 
which  is  specified  may  result  in  fire  or  electric 
shock.

 

 

Do not cut the link otherwise damage nor modify 
the 

power supply cord. In addition, avoid using 

the 

power  cord  in  close  proximity  to  heaters,  and 

never 

place  heavy  objects  -  including  the  unit 

itself - on the power cord, as doing so may  result 
in fire  or 

electric shock.

 

 

Be sure to replace the unit's terminal cover after 

connection completion. Because high voltage 
is 

applied to the speaker terminals, never touch 

these 

terminals to avoid electric shock.

 

 

Be sure to ground to the safety  ground (earth) 
terminal to avoid electric shock. Never ground 

to a gas pipe as a catastrophic disaster may result.

 

 

Avoid installing or mounting  the unit in unstable 

locations, such as on a rickety table or a slanted 

surface. Doing so may result in the unit  falling 

down, causing  personal injury and / or property 

damage.

 

Should  the  following  irregularity  be  found  during 

use,  immediately  switch  off  the  power,  disconnect 

the power  supply  plug  from  the AC outlet  and contact 
your  nearest  dealer.  Make  no  further  attempt  to 

operate the unit in this condition as this may cause 

fire or electric shock.

 

If you detect smoke or a strange smell coming

 

from the unit.

 

If water or any metallic object gets into the unit

 

If the unit falls, or the unit case breaks

 

If the power supply cord is damaged (exposure 

of the core, disconnection, etc.)

 

If it is malfunctioning (no tone sounds.)

 

 

 

To prevent a fire or electric shock, never open nor 
remove the unit case as there are high voltage 
components inside the unit. Refer all servicing

 

to your nearest dealer.

 

 

Do not place cups, bowls, or other containers of 
liquid or metallic objects on top of the unit. If they 
accidentally spill into the unit, this may cause a 
fire or electric shock.

 

 

Do not insert nor drop metallic objects or flammable 
materials in the ventilation slots of the unit's cover, 
as this may result in fire or electric shock.

 

Содержание CX4.100

Страница 1: ...CX4 180 CX4 240 Professional Class D Four Channel Amplifier Please follow the instructions in this manual to obtain the optimum resultsfrom this unit We also recommend that you keep this manual handy...

Страница 2: ...RES 3 4 EFFICIENCY 4 5 POWER SUPPLY 4 6 SUITABLE APPLICATION 4 7 NOMENCLATURE AND FUNCTIONS 7 1 Front Panel 5 7 2 Rear Panel 5 8 OPERATION INSTRUCTIONS 6 9 TROUBLE SHOOTING 6 10 APPLICATIONS 7 11 BLOC...

Страница 3: ...the unit itself on the power cord as doing so may result in fire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is applied to the speak...

Страница 4: ...is is an indication of a malfunction which in turn can cause heat to generate and result in a fire Do not block the ventilation slots in the unit s cover Contact your dealer as to the cleaning If Doin...

Страница 5: ...this new modulation method offers guarantee for some tiny signal sampling complete the form In addition we also increased the fixed switching frequency of the power precise controlled of the dead zone...

Страница 6: ...st not affected by output constraints because of the influence of music on average power density even the volume of the traditional power amplifier and digital power amplifier set to be the same we wi...

Страница 7: ...ntrol 6 CH C output level meter 7 CH D output level meter 8 CH D volume control 9 Air inlet 10 Power switch Rear Panel 11 AC Power socket 12 Speed control cooling fan 13 CH D signal XLR input 14 CH C...

Страница 8: ...ork properly 2 Power off 2 1 Adjust the volume knob counterclockwise to the minimum 2 2 Turn off the switch set to OFF position 2 3 Turn off the professional digital amplifier set to OFF Then turn off...

Страница 9: ...7 12 10 CONNECTION DIAGRAM...

Страница 10: ...8 12 11 BLOCK DIAGRAM...

Страница 11: ...ponse 20Hz 20KHz at 0 3dB IMD SMPTE 0 3 THD 1kHz 0 3 1dB below clip Damping Factor 8 800 Slew Rate 50V s Signal Noise Ratio 105dB Input Sensitivity 1V Voltage Gain 32dB 35dB 36dB 38dB 39dB 40dB Input...

Страница 12: ...rovider Variations and Options Variations Products supplied through legitimate sources are compatible with local AC power requirements Warranty Warranty terms of global three years While the term and...

Отзывы: