background image

4

INSTALLATION

DANGER

Electric Shock Hazard. Be sure to turn power OFF and disconnect from power source 

before any work is performed. Failure to do so could result in serious injury or death. 

PREPARATION

Open the unit door and locate the bracket that mounts the ozone modules and power supplies – most 

of this subassembly will be replaced

.

NOTICE

 The wire harness will be reused and does not need to be removed from the unit during 

service. Take care not to damage any wires or connectors during the process. 

DISCONNECTING THE MANIFOLD

Locate the ozone outlet barb. On the inside of unit, remove tubing clamp and disconnect the manifold 

tube from the ozone outlet barb.

 

WARNING

Trace amounts of nitric acid may be present in the tubing. Wear proper safety equipment 

(gloves and eye protection) and avoid direct contact with any condensation in the line. 

REMOVING THE OZONE SUBASSEMBLY

 (Refer to Figure 1)

1.  Disconnect all the ozone module power connectors.

2. Loosen the terminal block from the ozone bracket by removing the two mounting screws. 

3. Loosen the line filter (ECE models only) from the bracket by removing the two mounting screws.

4. Remove the two mounting nuts of the ozone bracket and remove the bracket with ozone modules, 

power supplies and manifold.  

5. Carefully remove zip-ties as necessary to free subassembly from unit. 

6. The wire harness, terminal block and line filter (ECE models only) will remain in the unit.  

INSTALLING THE NEW SUBASSEMBLY

 (Refer to Figure 2)

1.  Install the new bracket subassembly using the nuts previously removed.

2. Mount the line filter (ECE models only) to the new bracket using the screws previously removed

3.  Mount the terminal block to the new bracket using the screws previously removed.  

 

NOTICE

 For DEL Ozone 25 and 50, the terminal block requires 90° rotation to mount to the new 

bracket – the unit wire harness will allow it to reach but it may require adjustment and/or removal of 

zip-ties. 
4. Connect the new ozone module power connector(s) to any of the available positions.

RECONNECTING THE MANIFOLD

1.  Ensure that the new manifold is connected to all ozone modules. 

2. Install new tubing clamp over the new manifold tube, connect tube to the ozone outlet barb and 

secure with new tubing clamp.

SYSTEM STARTUP

Restore power to the unit and check proper operation, including that the ozone module light(s) are 

illuminated. Close unit door.

Содержание DEL Ozone 100

Страница 1: ...4 2836 01 Rev A C M P COM DEL DEL OZONE 25 50 100 OZONE UPGRADE SERVICE INSTRUCTIONS ...

Страница 2: ...ting electrical equipment Install in accordance with the installation instructions Follow all applicable electrical codes DANGER ELECTRIC SHOCK HAZARD Be sure to turn power OFF and disconnect from power source before any service work is performed Failure to do so could result in serious injury or death The DEL Ozone must be installed in an outdoor location or indoors in a forced air ventilated roo...

Страница 3: ...re U S patents or pending patent applications See c m p com patents for details Preparation 4 Disconnecting the Manifold 4 Removing the Ozone Subassembly 4 Installing the New Subassembly 4 Reconnecting the Manifold 4 System Start Up 4 TABLE OF CONTENTS ...

Страница 4: ...om the bracket by removing the two mounting screws 4 Remove the two mounting nuts of the ozone bracket and remove the bracket with ozone modules power supplies and manifold 5 Carefully remove zip ties as necessary to free subassembly from unit 6 The wire harness terminal block and line filter ECE models only will remain in the unit INSTALLING THE NEW SUBASSEMBLY Refer to Figure 2 1 Install the new...

Страница 5: ... 50 Power Connector s Ozone Module s Ozone Outlet Manifold Tubing Clamp Mounting Screw Terminal Block Line Filter optional FIGURE 2 NEW OZONE SUBASSEMBLY DEL Ozone 100 DEL Ozone 25 DEL Ozone 50 Power Connector s Ozone Module Ozone Module Light s Ozone Outlet Manifold Tubing Clamp ...

Страница 6: ...m Below Keep for Your Records Installer _______________________________________________________________ System Purchased From ______________________________________________ Installation Date _____________________________ Serial Number _______________________________ ...

Страница 7: ...7 NOTES ...

Страница 8: ...CMP LLC 36 HERRING ROAD NEWNAN GA 30265 WWW C M P COM DEL 0621AB ...