If local codes require a piping system pressure test including this vessel, BE 

SURE TO COMPLY WITH THE FOLLOWING SAFETY INSTRUCTIONS:

•  Check all clamps, bolts, lids, lock rings and system accessories to 

ensure they are properly installed and secured before testing.

•  RELEASE ALL AIR in the system before testing.
•  Water pressure for test must NOT EXCEED 35 PSI.
•  Water temperature for test must NOT EXCEED 100°F (38°C).
•  Limit test to 24 hours. After test, visually check system to be sure it 

is ready for operation.

General Information

The DEL MDV XL will effectively separate ozone bubbles from the 

ozonated water produced by the DEL AOP and DEL Ozone. When the 

flow enters the MDV XL, the ozone bubbles are allowed to float up and 

accumulate at the top as the water exits out the bottom. The separated 

ozone passes through a float valve and is sent through a carbon 

destruct and neutralized to safely vent to the atmosphere.
The MDV XL should be used in all indoor, covered, and vinyl lined 

pools where there is an AOP installed. It can also be used in outdoor 

applications to eliminate bubbles in your return flow.

OVERVIEW

Figure 1a: System View

RETURN

TO POOL

FILTER

AOP

SANITIZER

HEATER

MDV XL

BALL VALVE

(OPTIONAL)

PUMP