Evaluation Kit for CMX7x6x
PE0601-xxxx
©
2011 CML Microsystems Plc
26
UM0601/2
6.3
Function Image
TM
There are two methods by which a FI may be loaded into the CMX7x6x device.
Whenever power is removed from the PE0601 the FI data will be erased from the CMX7x6x
device. Therefore, whenever power is applied a FI must be loaded, either from the serial memory
or via the C-BUS interface.
If the PE0601 is used with the PE0002 evkit interface card, function images can be loaded as
described in sections 6.3.1, 6.3.2 and 6.3.3.
6.3.1 Load Function Image
TM
via C-BUS
Use the ‘Function Image™ Load’ tab. Select Function Image™ Source: ‘C-BUS’.
•
Enter the name of the file containing the Function Image™, or navigate to the required file
using the ‘Browse’ button.
•
Select target board.
•
Click the ‘Load’ button. The progress of the download is shown visually on the progress bar
and when the download has completed a message box will be displayed indicating if the
result of the download operation was successful or not.
Figure 5 – Function Image™ Load Tab – via C-BUS