![CML Microcircuits PE0403 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/cml-microcircuits/pe0403/pe0403_user-manual_2627455020.webp)
Evaluation Kit for CMX724x/CMX734x
PE0403
2014 CML Microsystems Plc
20
um0403/1
6.3.
Function Image
TM
There are two methods by which a FI may be loaded into the CMX7240/CMX7340 device.
Whenever power is removed from the PE0403 the FI data will be erased from the CMX7240/CMX7340
device. Therefore, whenever power is applied a FI must be loaded via the C-BUS interface.
If the PE0403 is used with the PE0002 PC interface, Function Images can be loaded as described in
sections 6.3.1, 6.3.2 and 6.3.3.
6.3.1. Load Function Image
TM
via C-BUS
Use the Function Image
™ Load tab. Select Function Image™ Source: ‘C-BUS’.
Enter the name of the file containing the Function Image
™, or navigate to the required file using the
‘Browse’ button.
Enter the activation code in the lower edit box. Alternatively select one of two previously used codes in
the drop down list.
Select Target Board.
Click the “Load” button. The progress of the download is shown visually on the progress bar and when
the download has completed a message box will be displayed indicating if the result of the download
operation was successful or not.
Figure 6 Function Image
™ Load Tab – via C-BUS