CML Microcircuits CMX7143 Fl Series Скачать руководство пользователя страница 2

Application Note 

CMX7143_FI-x Configuration Guide

 
 

© 2009 CML Microsystems Plc     

2 of 5

 

 AN/WData/7143/Config/5 November 2009

 

CH3 / 

RSSI3

VBIAS

VBIAS

VBIAS

$C0

b14=0 Powersaved

b14=1 Enabled

$C0

b15=0 Powersaved

b15=1 Enabled

$C0

b13=0 Powersaved

b13=1 Enabled

00

01

10

11

00

01

10

11

VBIAS

VBIAS

RSSI Enable
$C0, b2

0=Disabled

1=Enabled

$B1 b3,2

RSSI Gain
$B1, b15-13

000=0dB

001=3.2dB
010=6.4dB
011=9.6dB
100=12.8dB
101=16dB
110=19.2dB
111=22.4dB

Rx Signal Gain
$B1, b12-10

000=0dB

001=3.2dB
010=6.4dB
011=9.6dB
100=12.8dB
101=16dB
110=19.2dB
111=22.4dB

RSSI Signal 

Routing

$B1 b5,4

Rx Signal 

Signal 

Routing

0

1

MOD1 Enable
$C0, b9

0=Disabled

1=Enabled

MOD1 Coarse Attenuation
$CD, b13-11 (dB)

000=>40

001=12
010=10
011=8

MOD2 Enable
$C0, b8

0=Disabled

1=Enabled

MOD2 Course 
Attenuation
$CD, b6-4 (dB)

000=>40

001=12
010=10
011=8

VBIAS

VBIAS

MOD2 
Source
$B1, b7

MOD1 Source
$B1, b9

0

1

Tx Mode

Test 

Mode

Mod1 Signal Enable
$C0, b11

0=Disabled

1=Enabled

Mod2 Enable
$C0, b10

0=Disabled

1=Enabled

Tx 

Modulator

Mode

RSSI Fine 
Input Gain
P 4.1
0-> -3.5dB
Default:

$8000 =0dB

Rx Signal  
Fine Input 
Gain
P 4.0
0-> -3.5dB
Default: 

$8000 = 0dB

100=6
101=4
110=2
111=0

100=6
101=4
110=2
111=0

Rx Signal  
Enable
$C0, b12

0=Disabled

1=Enabled

GPIO4

 GPIO Switches

$CD, b15-14 and b3-0

0=Disabled

1=Enabled

GPIO1

GPIO2

GPIO3

GPIO

b0

b1

b2

b3

Internal 

Bias

Block

VBIAS

BIAS Enable

$C0, b6

0=Disabled

1=Enabled

CH2 / 

RSSI2

CH1 / 

RSSI1

Idle Mode

$C1, b1-0 = 00

Tx Modem and CS Modem Control 
$C1, b7-4

0000 = Idle

0001 = Reserved
0010 = Tx Raw Data Only
0011 = Tx PRBS
0100 = Tx Preamble, Sync1, Raw Data
0101 = Tx Preamble, Sync2, Raw Data
0110 = Test – Deviation
0111 = Reset / Abort
1000 = Test – Preamble
1001 = Reserved
1010 = Tx Preamble, Sync1, Formatted Data
1011 = Tx Preamble, Sync2, Formatted Data

Rx Modem Control
$C1, b11-8 

0000 = Idle

0001 = Reserved
0010 = Rx search for Sync1 or 2, then Rx Raw Data
0011 = Rx eye 
0100 = Rx search for Sync1, then Rx Raw Data
0101 = Rx search for Sync2, then Rx Raw Data
0110 = Reserved
0111 = Reset / Abort
1000 = Reserved
1001 = Rx search for Sync1 and 2, then Rx Formatted Data
1010 = Rx search for Sync1, then Rx Formatted Data
1011 = Rx search for Sync2, then Rx Formatted Data

CS Modem Control
$C1, b7-4 

0000 = Idle

0001 =  Reserved
0010 = Tx Raw Data Only
0011 = Tx PRBS
0100 = Tx Preamble, Sync1, Raw Data
0101 = Tx Preamble, Sync2, Raw Data
0110 = Test – Deviation
0111 = Reset / Abort
1000 = Test – Preamble
1001 = Reserved
1010 = Tx Preamble, Sync1, Formatted Data
1011 = Tx Preamble, Sync2, Formatted Data

Levels tracking behaviour
$C1, b15-14

00 = Locked: no tracking

01 = Track levels on, slow response
10 = Track levels on, fast response
11 = Auto-tracking response 
dynamically selected.

Symbol timing PLL behaviour
$C1, b13-12

00 = Locked: no tracking

01 = Narrow PLL
10 = Medium PLL
11 = Auto-PLL bandwidth 
dynamically selected

1

Burst Data Configuration

$C8, Block 0 

P0.0 - P0.10

Burst Tx Se GPIO Configuration

$C8, Block 1 

P1.0 – P1.13

Gain and Offset Setup

$C8, Block 4 

P4.0 – P4.10

Programming Register $C8

2

3

4

Transmit Mode
$C1, b1-0 = 10

Tx Data Buffer

Channel Encoding

GMSK/

GFSK 

Modulator

GMSK/GFSK

Filter

Data Modulator

2

Raw Data

Formatted Data

RSSI 

Detection

Carrier Sense Mode

$C1, b1-0 = 11

4

Rx Data Buffer

Receive Mode

$C1, b1-0 = 01

3

5

Channel 

Decoding

Data Demodulator

GMSK/GFSK

Filter

AFSD

GMSK/GFSK 

Demodulator

Formatted 

Data

Rx Eye

Raw Data

Modem Mode and Control Register $C1

Modem Mode and Control Register $C1

6.0

6.1

6.2

See 

6.1

See 

6.2

See 

6.2

1

RSSI 

Detection

AFSD

Tx/Rx Data Registers

Note 1: CMX7143 – FI1.  
When transmitting two part data blocks part 1, then part 2 must be loaded in 
consecutive transactions before any data is sent. This is necessary due to 
interleaving.

OR

True

False  for 

CS period

Carrier  

Sense

Frame

Sync

CMX7143_FI1 GMSK/GFSK Multi-mode Packet-data Modem

5

MOD1 Fine Attenuation
$CD, b10-7 (dB)

0000=0

0001=0.2
0010=0.4
0011=0.6
0100=0.8
0101=1.0
0110=1.2
0111=1.4
1000=1.6
1001=1.8

MOD2 Fine Attenuation
$CD, b3-0 (dB)

0000=0

0001=0.2
0010=0.4
0011=0.6
0100=0.8
0101=1.0
0110=1.2
0111=1.4
1000=1.6
1001=1.8

Tx Bytewise Formatted Data T ransmit

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

$B5 TxData0
$B6 TxData1
$B7 TxData2
$CA TxData3
$CB TxData4
$C2 TxData5
$C7 TxData6

TxData_Byte 3

TxData_Byte 12

TxData_Byte 11

TxData_Byte 10

TxData_Byte 9

bit

Block Spec if ier (N ote 1)

Trans Count

TxData_Byte 0

TxData_Byte 4

TxData_Byte 1

TxData_Byte 8

TxData_Byte 7

TxData_Byte 6

TxData_Byte 5

TxData_Byte 2

Rx Bytewise Formatted Data Receive

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

$B8 RxData0

CRC

$B9 RxData1
$BA RxData2
$BB RxData3
$C5 RxData4
$C9 RxData5

$CC RxData6

bit

Block Spec if ier (N ote 1)

RxData_Byte 5

RxData_Byte 4

RxData_Byte 3

RxData_Byte 2

RxData_Byte 1

RxData_Byte 0

Trans Count

RxData_Byte 11

RxData_Byte 10

RxData_Byte 9

RxData_Byte 8

RxData_Byte 7

RxData_Byte 12

RxData_Byte 6

Tx Bytewise Raw Data Transmit

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

$B5 TxData0

1

$B6 TxData1
$B7 TxData2
$CA TxData3
$CB TxData4
$C2 TxData5
$C7 TxData6

TxData_Byte 2

Trans Count

TxData_Byte 4

TxData_Byte 3
TxData_Byte 5

TxData_Byte 12

TxData_Byte 11

TxData_Byte 10

TxData_Byte 9

bit

TxData_Byte 0

Byte Counter

TxData_Byte 1

TxData_Byte 8

TxData_Byte 7

TxData_Byte 6

Rx Bytewise Raw Data Receive

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

$B8 RxData0

1

$B9 RxData1
$BA RxData2
$BB RxData3
$C5 RxData4
$C9 RxData5

$CC RxData6

Byte Counter

Trans Count

RxData_Byte 0

bit

RxData_Byte 1

RxData_Byte 2

RxData_Byte 3

RxData_Byte 4

RxData_Byte 5

RxData_Byte 6

RxData_Byte 11

RxData_Byte 12

RxData_Byte 7

RxData_Byte 8

RxData_Byte 9

RxData_Byte 10

Tx Bitwise Raw Data T ransmit

15 14

13 12 11

10

9

8

7

6

5

4

3

2

1

0

$B5 TxData0

b0 b1

b2 b3 b4

b5 b6

b7

0

$B6 TxData1

b8 b9 b10 b11 b12 b13 b14 b15 b16 b17 b18 b19 b20 b21 b22 b23

$B7 TxData2 b24 b25 b26 b27 b28 b29 b30 b31

bit

Trans  Count

Bit Counter

Rx Bitwise Raw Data Receive

15 14

13 12 11

10

9

8

7

6

5

4

3

2

1

0

$B8 RxData0

b0 b1

b2 b3 b4

b5 b6

b7

0

$B9 RxData1

b8 b9 b10 b11 b12 b13 b14 b15 b16 b17 b18 b19 b20 b21 b22 b23

$BA RxData2 b24 b25 b26 b27 b28 b29 b30 b31

bit

Trans  Count

Bit Counter

Содержание CMX7143 Fl Series

Страница 1: ...nction ImagesTM 7143FI 1 0 4 0 7143FI 2 1 2 0 7143FI 3 0 3 0 This Configuration Guide is not intended to cover all of the hardware functions or possible set up modes It is a virtual representation of the device and is provided for illustrative purposes to simplify and aid product development Default settings are given in red and control paths are shown in blue The Configuration Guide is best print...

Страница 2: ... 10 Programming Register C8 2 3 4 Transmit Mode C1 b1 0 10 Tx Data Buffer Channel Encoding GMSK GFSK Modulator GMSK GFSK Filter Data Modulator 2 Raw Data Formatted Data RSSI Detection Carrier Sense Mode C1 b1 0 11 4 Rx Data Buffer Receive Mode C1 b1 0 01 3 5 Channel Decoding Data Demodulator GMSK GFSK Filter AFSD GMSK GFSK Demodulator Formatted Data Rx Eye Raw Data Modem Mode and Control Register ...

Страница 3: ...riod Carrier Sense Frame Sync CMX7143_FI2 4 Level FSK Packet data Modem MOD1 Fine Attenuation CD b10 7 dB 0000 0 0001 0 2 0010 0 4 0011 0 6 0100 0 8 0101 1 0 0110 1 2 0111 1 4 1000 1 6 1001 1 8 MOD2 Fine Attenuation CD b3 0 dB 0000 0 0001 0 2 0010 0 4 0011 0 6 0100 0 8 0101 1 0 0110 1 2 0111 1 4 1000 1 6 1001 1 8 Levels tracking behaviour C1 b15 14 00 Locked no tracking 01 Track levels on slow res...

Страница 4: ...c and modulation as defined by P4 1 then Rx Raw Data 0011 Rx eye 0100 Reserved 0101 Reserved 0110 Reserved 0111 Reset Abort 1000 Reserved 1001 Rx search for Sync and modulation as defined by P4 1 then Rx Formatted Data CS Modem Control C1 b7 4 0000 Idle 0001 Reserved 0010 Tx Raw Data Only 0011 Tx PRBS 0100 Tx Preamble Sync1 Raw Data 0101 Tx Preamble Sync2 Raw Data 0110 Test Deviation 0111 Reset Ab...

Страница 5: ...ied CML reserves the right at any time without notice to change the said algorithms methods and circuitry and this product specification CML has a policy of testing every product shipped using calibrated test equipment to ensure compliance with this product specification Specific testing of all circuit parameters is not necessarily performed ...

Отзывы: