PRECAUTIONS 

IMPORTANT 

Always follow the basic precautions listed below to avoid the possibility of serious injury or 

even death from electrical shock, damages, fire or other hazards. These precautions 

include, but are not limited to, the follows:   

1

 Read and understand all the instructions.   

2

 Always follow the instructions on the instrument.   

3

 Before cleaning the instrument, always remove the electric plug from the outlet as well 

as the USB cable. When cleaning, use a soft and dry cloth. Do not use gasoline, 

alcohol, acetone, turps or any other organic solutions; do not use liquid cleaner, spray 

cleaner or too wet cloth.   

4

 Do not use the instrument near water or moisture, such as bathtub, washbasin, 

washing poor in the kitchen or similar places.   

5

 Do not place the instrument in an unstable position where it might accidentally fall over.   

6

 Do not jam sinks or holes of the instrument; those sinks of holes are used for air 

circulation to prevent the instrument from overheating. Do not place the instrument 

near heat sink or any places with poor air circulation.   

7

 Do not place anything on the power cord. Make sure the power cord is set on a safe 

place, so nobody will step on it and no body will    trip over it.   

8

 Do not overload the outlet and the AC cable to avoid fire or electrical shock.   

9

 Do not insert anything in the instrument, which may cause fire or electrical shock. Do 

not splash any kind of liquid to the instrument.   

10

 

Do not disassemble the instrument in case of accidental electrical shock.   

11

 

Always take the instrument to a qualified service center in need of repair. You will 

cause yourself in danger if you open or remove the cover, and improper assembly may 

cause electrical shock in the future use.   

12

 

Unplug all the connectors and take the instrument to a qualified service center if 

anything in the below listed happens:   

1

 

The power cord or connector get hurt or worn out.   

2

 

Any liquid get in the instrument.   

3

 

The instrument gets rain or water splash.   

4

 

The instrument dose not work properly after following all the instructions 

regarding to the trouble shootings.   

5

 

The instrument falls down or gets broken. 

6

 

The instrument functions poorly.   

 

  Do not connect the instrument when thundering.   

 

  Do not set up the cord or outlet to a moist place, except for that the outlet is specially 

designed for moist places. 

 

  When the power cord is connected to the AC outlet, do not touch the naked part of the 

cord or the connector. 

Always follow the instructions carefully when setting up the instrument.   

        Do not expose the instrument to rain or moisture, to avoid fire or electrical shock.   

Содержание WIDI-XU

Страница 1: ...Wireless MIDI Interface User s Manual Model WIDI XU Read Precautions on page 5 before use Please ready this manual carefully before use Please keep this manual for reference...

Страница 2: ...d or another products use only high quality shielded cables Cable s supplied with this product MUST be used Follow all installation instructions Failure to follow instructions could void your FCC auth...

Страница 3: ...lied by CME are designed for the respective products only No other uses are recommended NOTICE Service charges incurred due to a lack of knowledge relating to how a function or effect works when the u...

Страница 4: ...o communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which ca...

Страница 5: ...trip over it 8 Do not overload the outlet and the AC cable to avoid fire or electrical shock 9 Do not insert anything in the instrument which may cause fire or electrical shock Do not splash any kind...

Страница 6: ...nstrument to sunlight Do not place heavy objects on the instrument do not place containers with liquid on the instrument Do not touch the connectors with wet hands Central Music Co is not responsible...

Страница 7: ...tion 9 3 1 Power supply 9 3 2 Connection 9 3 3 Routing 10 3 4 Radio channel setting 10 3 5 Removal of the product 11 4 Automation 12 4 1 Automatic communication establishing 12 4 2 Automatic notes off...

Страница 8: ...porting hot plug When connected to computer via USB this product will be automatically recognized as the USB Audio Device fully support MIDI data stream compatible with Cakewalk Sonar Cubase etc USB p...

Страница 9: ...or The indicator has two colors red for power indicator and green for signal indicator 3 1 Power supply WIDI XU uses USB bus power If it is the first time the WIDI XU is connected to the computer the...

Страница 10: ...e manually setting is via sending system control command You can use software such as Cakewalk to send system control command or use WIDI Control EXE an easily control software from CME Below are syst...

Страница 11: ...the same radio channel The WIDI system supports up to 32 pairs of WIDI devices used at the same place If you use many pairs of WIDI devices at the same place to ensure better performance please set th...

Страница 12: ...g after radio channel changed When the radio channel is changed the WIDI XU will automatically establish communication 4 2 Automatic notes off In either one of the following cases the system will auto...

Страница 13: ...e USB Audio device before you unplug the WIDI XU Reduce the obstacle and interference as much as possible If the signal indicator blinks it means there is interference If the signal indicator blinks f...

Страница 14: ...er free radio channel 4 Turn on RF F0 00 20 63 00 07 02 02 10 6F F7 Turn on the RF transmitting receiving function 5 Turn off RF F0 00 20 63 00 07 02 02 10 60 F7 Turn off the RF transmitting receiving...

Страница 15: ...15 2006 Sep Central Music Co Tel 86 10 8580 1115 Fax 86 10 8580 1114 Web www cme pro com E mail for support support cme pro com...

Отзывы: