CMC Wood Insert Скачать руководство пользователя страница 2

Installation Instructions

 

Page 2 

PLEASE NOTE:

 

Your 

CMC Wood Insert

 must be assembled and installed correctly. 

Please read and follow all instructions carefully.  Incorrect assembly or installation could result in a damaged 

CMC

Wood Insert

 and/or a dangerous condition.  Failure to heed these warnings could result in a fire and/or loss of life and 

property.  If you do not feel confident that you are equipped to complete the assembly and the installation properly 
please contact 

Fireplace Doors Online

 

WARNING:

 

The 

CMC Wood Insert

 is not designed for installation into factory built “zero-clearance” (ZC) fireplaces, 

nor for installation into mobile homes, nor in conjunction with gas log sets. 

NOTICE:

 

Any fireplace used for the installation of a 

CMC Wood Insert

 must comply with NFPA 211, The Standard for 

Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances. 

If you have questions:

 Contact 

Fireplace Doors Online

 before proceeding with installation. 

INSTALLATION: 

 

Inspect the fireplace and the chimney flue for signs of loose mortar, damaged brick, and creosote build-up.  If repairs are 

indicated contact a professional chimney sweep to arrange an inspection. 

○  Clean the fireplace to remove all ashes and wood debris as necessary. 

 

Check the floor of the fireplace with a level front to back.  If the fireplace is pitched toward the back the leveling bolts will 
be used.  If the fireplace floor is pitched toward the front, the front of the 

CMC Wood Insert

 will need to be shimmed up. 

 

Unpack the 

CMC Wood Insert

 carefully and inspect for any signs of damage. 

○  If damage is noted please contact 

CMC

 for instructions. 

 

Unlatch the Doors and remove them by lifting straight up.  Remove the Mesh Screen Doors.  Set these parts safely aside. 

 

Assemble the Lintel Clamps by threading an adjusting nut onto each 6” bolt and adding the Lintel Bracket.  

(Figure 2)

 

○  Thread the Lintel Clamp Bolts into the nuts welded onto the back of the 

CMC Wood Insert

 face. 

 

Install the 

CMC Wood Insert

 into the fireplace and center it from side to side. 

○  If the fireplace is pitched toward the back install the leveling bolts into the tabs inside the back corners of the 

CMC

 

Wood Insert

.  The bolts thread in from the top leaving the bolt heads accessible for adjustment.  Adjust as necessary. 

○  If the fireplace floor is pitched toward the front, the front of the 

CMC Wood Insert

 will need to be shimmed up using non-

combustible spacers such as steel washers.  Seal the gaps between the shims with insulation as necessary. 

○  Install insulation strips between the 

CMC Wood Insert

 top and sides and the face of the fireplace.  Cover all gaps without 

bunching the insulation.  Large gaps created by rough openings may require additional insulation. 

 

Through the front door opening rotate the Lintel Clamps up to grip the fireplace lintel.  Tighten the adjusting nuts snugly. 

 

The power cord is preinstalled to exit to the left side (facing the 

CMC Wood Insert

).  To route the power cord to the right 

side, remove the Cord cover, (it is attached with magnets) reroute the cord, and reinstall the Cord Cover. 

 

Reinstall the Mesh Screen Doors and the Firebox Glass Doors. 

Fireplace 

Lintel 

Lintel 

Bracket 

Wood

 

Insert

Figure 2 

Mounting Nut 

3/8-16 x 6” Bolt 

& Adjusting Nut 

Lintel Clamp 

Fireplace 

Face 

Bypass 

Toggle Switch 

Variable Speed 

Fan Switch 

Cool Air Intake 

Blower 

(Behind Vent) 

Firebox 

Heated Air 

Delivery Vents 

Combustion Air 

Damper 

Figure 1 

Cord Cover 

Denali

 Style 

Wood Insert

 

PARTS INCLUDED FOR INSTALLATION:

 

OPTIONAL ACCESSORIES: 

2 ea.  Lintel Clamp Brackets 

2 ea.  3/8-16 x 2” Leveling Bolts 

Stainless Steel Grill 

2 ea.  3/8-16 x 6” Lintel Clamp Bolts 

1 ea.  Roll of Insulation 

Swinging Pot Holder 

2 ea.  3/8-16 Lintel Clamp Nuts 

1 ea.  Owner’s Manual 

 