CMC Mid-West 140 Скачать руководство пользователя страница 6

 

 

 

BULLETIN NO. ELEC-IM140/1

1

  

Replaces 

ELEC-IM140-141/09A

 

Instrument

Mid-West

®

 

CE Marking Statements: 

 
  The Electrical Configurations A,B, E, & F of this product are CE marked in compliance with the Low Voltage Directive to EN-61010-1. 
 
  These products shall not be placed in an Explosive atmosphere as defined by the ATEX Directive 94/9/EC except  if evaluated to be “Simple 
 Apparatus”. 
 
  They may be classified as simple apparatus.  However, the evaluation to the relevant portions of the applicable standards and clearly 
  identifying the product as simple apparatus shall be the responsibility of the end user. 
 
  The Pressure Equipment Directive has been determined to be 

non applicable for CE marking

.  These products are manufactured in accordance 

  with article 3, paragraph 3 of the directive, “sound engineering practice”.  They fall below category I for non-hazardous gases, hazardous liquids, 
  & non-hazardous liquids.  This product also falls below category I for hazardous gases at or below 200 bar.  
 
 

 

Simple Apparatus NEC 504.2 

 
 

The A, B, E, & F Electrical configurations of this product meet the simple apparatus definition as defined in NEC 504.2 of Article 504 

 

(Intrinsically Safe Systems).  Because of this classification, equipment listing is not required (504.4) and ordinary wiring methods shall be 

 

permitted (504.20).  Proper installation of this product in a hazardous location to the applicable requirements is the responsibility of the end  user / 

 

equipment installer.  

 

EMC Directive:     
 
The transmitter design has been evaluated to and passed the following “EN” Standards as they relate to the EMC directive.  However,  the 
units are not CE marked for compliance to the EMC directive. 

 

IEC EN61326:1997 Environment Industrial, Electrical Equipment for measurement, Control and Laboratory use,  
EMCrequirements from which: 
 
EN55011:1998Emission standard for Industrial, Scientific and Medical Equipment, Class A 
EN61000-4-2:1995 Electrostatic discharge (ESD) immunity 
EN61000-4-3:1996 Radiated EM field immunity 
ENV50204:1995 Radiated EM field immunity from digital telephones (GSM) 
EN61000-4-4:199 5Electrical fast transient (EFT) immunity 
EN61000-4-5:1995 Surge immunity 
EN61000-4-6:1996RF conducted immunity 
EN61000-4-8:1993 Power Frequency magnetic field 

 
 

 

Warning:

 

The suitability of the application and installation of this differential pressure switch / transmitter is the 

responsibility of the end user. The applicable certifications, listings apply to the differential 
pressure switch / transmitter only.

 

 
 
 
 
Mid-West

 

Instrument 

6500 Dobry Dr.  Sterling Heights, MI  48314 
(586)254-6500  FAX (586)254-6509 
E-Mail:  

[email protected]

 

Web Page: 

www.midwestinstrument.com

 

PROOF PRESSURE:

  2X Working Pressure 

 

 

 

Warranty

:  5 Years     Transmitter (1 Year) 

WORKING PRESSURE:  

3,000 PSI  (AL, SS)   1500 PSI (Brass) 

 
TEMPERATURE LIMITS:

 

-40

F to + 200

F

  (Switch Options);  -20

 F TO + 150

 F (Transmitter Option)   

These limits are based on the entire instrument being saturated to these temperatures.  System (process) temperatures may exceed 
these limitations with proper installation. Contact our customer service representative for details. 

CMC TECHNOLOGIES 

P

TY

 L

IMITED

 ACN: 47 085 991 224    ABN: 47 085 991 224 

 

Phone: 

 

+61 2 9669 4000   

 

 

 

Unit 19, 77 Bourke Rd 

Engineering &

 Fax: 

 

 +61 

9669 

4111 

    Alexandria 

Industrial

  

Email: 

 

[email protected]

  

 

NSW  2015 

Instrumentation

 Website:

 

www.cmctechnologies.com.au

  

 

AUSTRALIA 

 

Отзывы: