background image

 

 

 

 

 

CMC Rescue, Inc. 

|

 A Z VORTEX User’s Manual  

14 

 

Gin Pole 

 

A Gin Pole or “monopod” should have a minimum of three guy lines spaced at 120˚ angles. 

If anchor availability permits, four guy lines spaced at 90° angles makes the set-up even more 
secure, 

Figure 14

. The ground end of the pole should be secure, either anchored to the surface 

or placed in a natural opening or hole. As with the A-frame, the Gin Pole should be tilted so that 
the resultant force vector is directed down in line with the pole.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

 

 

The AZ VORTEX head has an ample number of holes for attaching the guy lines. The head 

should be positioned so that the Working Line clears the guy lines and does not torque the Gin 
Pole when the load is applied. 

 
 

 

 
 
 
 

Figure 14 

Содержание AZ VORTEX

Страница 1: ...V2 1 USER S MANUAL by Rock Exotica UL Classified to NFPA 1983 General Use EN 795...

Страница 2: ...ff or the structure With the adjustable leg lengths and the flexible third leg the AZ VORTEX lets rescuers set up an artificial high directional in virtually any urban industrial or wilderness locatio...

Страница 3: ...0 lbf 80 kN for the 3 8 inch leg pins 32 000 lbf 142 kN for the 1 2 inch head pins Safe working load 600 lbf 2 7 kN Standard AZ VORTEX Package The standard package comes complete with 1 Head Set 3 Upp...

Страница 4: ...press the foot into the soil All legs must still be independently hobbled to each other or to independent anchors Soft Soil Disturbed Raptor Foot Recommended A disturbed soil condition requires addit...

Страница 5: ...onfiguration While the User s Manual is not intended to teach everything necessary to safely operate this device it is the user s responsibility to read and understand the User s Manual that accompani...

Страница 6: ...ked over the edge VISUALIZING THE RESULTANT The resultant force vector R created by a Main Line under tension bisects the incoming vector F1 and the out going vector F2 One way to visualize where the...

Страница 7: ...cure it to an anchor behind the AZ VORTEX The resultant force on an A frame should be in line with the legs A line projected through the pin and pulley axle should be aligned with the legs The angles...

Страница 8: ...own commences This process will become less cumbersome with experience Each method has advantages and disadvantages depending on the location and the available personnel Practicing both will prepare t...

Страница 9: ...igure 5 is a standard practice for conventional tripods and works well with the AZ VORTEX For NFPA certified configurations each pair of feet must be independently hobbled With any tripod it is critic...

Страница 10: ...ipping hazards Using the AZ VORTEX as a Tripod The AZ VORTEX can be set up in a variety of tripod configurations including an equal leg tripod The adjustability of the AZ VORTEX allows it to fit a var...

Страница 11: ...s can be rigged in a more vertical position This allows the anchor points on the AZ VORTEX head to be placed closer to an edge or directly over an opening next to a wall or other barrier as shown in F...

Страница 12: ...ht down the legs the guy lines take additional loading and a guy line failure will cause a collapse For rescue teams already trained in and using improvised bipods and monopods the AZ VORTEX follows t...

Страница 13: ...s both in the front near or over the edge and in the back Additional guy lines may be needed to prevent the A frame from moving sideways if the load should shift To maximize the force supported by the...

Страница 14: ...om the edge the anchors are located along the edge rather than over it A Sideways A frame set up Figure 13 is guyed from both sides right and left which alleviates the need for an anchor point close t...

Страница 15: ...ound end of the pole should be secure either anchored to the surface or placed in a natural opening or hole As with the A frame the Gin Pole should be tilted so that the resultant force vector is dire...

Страница 16: ...the equipment should be removed from service If the AZ VORTEX is dropped or impact loaded it should be inspected by a qualified inspector prior to being returned to service In most cases a visual ins...

Страница 17: ...in Service Brand Model Size Date How Used or Maintained Comments Name Marking on the Product The orange component of the AZ VORTEX head is marked as follows CE 0120 EN 795 B and WARNING For Dangerous...

Страница 18: ...ngth 9 ft 2 7 m 2 Head unit connected to the upper leg via upper head pin hole and last upper leg pin hole 3 Use either Raptor or Flat Feet 4 Legs at equal distance apart 5 Feet are required to be ind...

Страница 19: ...r Main Line or Working Line The line used to move the load NFPA National Fire Protection Association Resultant Force The linear direction of the sum of all of the vector forces acting on the component...

Отзывы: