background image

RINSE 

INJECTION

110V POWER

CONNECTION

FOR DISPENSER

DETERGENT 

INJECTION

WASH

SENSOR

RINSE

SENSOR

3-2018

CMA PN: 10130.02

180UC 

Quick Setup 

Instructions

1

STEP

FLOOR DRAIN

1"AIR GAP

Connect the drain hose to wall or floor drain. The 

floor drain must have a 1 inch air gap between

drain hose and floor drain.

WALL

DRAIN

WARNING

: Electrical and plumbing 

connections need to be made by a 
qualified service technician and 
comply with all available Federal, 
State and Local Health, Electrical, 
Plumbing and Safety codes.

1/2" WATER INLET

DRAIN VALVE

PUMP DRAIN

MOTOR

LEVELING

LEGS

2

3

4

4

Connect dishmachine to hot water source, 

recommended minimum temperature 140°F. Unit 

will remain in wash cycle until booster heater 

temperature reaches 180°F, then it will advance into

rinse cycle.

3

STEP

When ever possible, 

remove pump drain if a floor

drain is available near by. Remove drain pipe and

place drain hose on the drain valve and allow

machine to gravity drain.

4

STEP

Level dishmachine by adjusting leveling legs. 

Dishmachine must be level front and back and 

side to side. 

2

STEP

NEUTRAL

HOT

GROUND

DRAIN HOSE

1

HARD WIRE

 FOUR WIRE

POWER SUPPLY

180UC REAR VIEW

NOT MORE

THAN 22"

HEIGHT FROM

FLOOR