23
P/N: 10001609 (REV AB) 627NH
December 2014
IMpulse G+MINI aDJustaBle freQueNcY DrIVe specIfIcatIoNs
Specification
Specification Value and Information for all Models
Certification
UL, cUL, CE, TüV, RoHS
Rated input power supply volts & frequency
3-phase 200~240V or 380~480V: 50/60 Hz
Allowable input voltage fluctuation
+10% or -15% of nominal
Allowable input frequency fluctuation
±5% of nominal
Control method
Fully digital; sine-wave, pulse-width-modulated
Maximum output voltage (VAC)
Max output voltage 3-phase, 200~240V; 380~480V (proportional to input voltage).
Rated frequency (Hz)
Up to twice motor nameplate RPM (Swift-Lift) 60 Hz standard (150 Hz, consult factory)
Output speed control range
40:1 -V/f, 100:1 - Open Loop Vector (OLV)
Output frequency accuracy
0.01%-with digital reference command
0.1%-with analog reference command; 10 bits/10V
Frequency reference resolution
Digital: 0.01 Hz; analog: 0.03 Hz (at 60 Hz)
Output frequency resolution
0.01 Hz
Overload capacity
150% of rated output current of the drive for 1 minute
Remote frequency reference sources
0-10VDC (2K
Ω
); ±10VDC serial (RS-485)
Accel/decel times
0.0 to 25.5 seconds - 1 set; 0.0 to 6000.0 - 3 sets;
8 parameters are independently adjustable
Braking torque
150% or more with dynamic braking
Motor overload protection
UL recognized electronic thermal overload relay: field-programmable
Overcurrent protection level
200% of drive rated current
Circuit protection
Ground fault and blown-fuse protection
Overvoltage protection level
Approximately 410VDC (230V Class), 820VDC (460V Class)
Undervoltage protection level
Approximately 190VDC (230V Class), 380VDC (460V Class)
Heatsink overtemperature
Thermostat trips at 184 - 249°F (90 -121°C) dependent on drive capacity
Torque limit selection
Separate functions for FORWARD, REVERSE, REGEN.; all selectable from 0-300%
Stall prevention
Separate functions for accel, decel, at-speed and constant horsepower region
Other protection features
Lost output phase, failed-oscillator, mechanical overload and internal braking transistor
DC bus voltage indication
Charge LED is on until DC bus voltage drops below 50VDC
Location
Indoors; requires protection from moisture, corrosive gases and liquids
Ambient operating temperature
14° to 122°F (-10° to 50°C) for open chassis
Storage temperature
-4° to 140°F (-20° to 60°C)
Humidity
95% relative; noncondensing
Vibration
1G less than 20 Hz; 0.2 G for 20-55 Hz
Elevation
3300 Ft. (1000M) or less
Memobus
RS485/422 Max 115.2 Kbps
Содержание Lodestar A
Страница 31: ...31 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Страница 32: ...32 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Страница 33: ...33 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Страница 34: ...34 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Страница 35: ...35 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Страница 36: ...36 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Страница 37: ...37 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Страница 38: ...38 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Страница 39: ...39 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Страница 40: ...40 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Страница 41: ...41 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Страница 42: ...42 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Страница 43: ...43 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Страница 44: ...44 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Страница 45: ...45 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Страница 46: ...46 00001996 REV AC 627NH October 2014 REFERENCE WIRING DIAGRAMS ...
Страница 95: ...95 00001996 REV AC 627NH October 2014 NOTES ...
Страница 127: ...31 P N 10001609 REV AB 627NH December 2014 Notes ...