If the black semi-conducti ve layer is 
not completely removed, reset blade 
according to 2.2.

Rotate the tool BSC in the direction 
indicated by the arrow (7) until the 
body touches the sheath (25mm)

7

F

The tools must be used on non-live cables by skilled workers who are competent in cable
preparation and know about electrical phenomenons.

F

Wearing gloves is obligatory.

F

Clean the tools after each use.

25mm

Spare blade

part no.  

BSC1ER

Silicone

, tube 35 g

Part no. 

Silicone

3. Removal of the BSC

Unlock bolt (2) 

Remove blade by turning screw (3)  
(see picture above)

Loosen nut (1)

Remove the BSC

1

2