![Club Car Villager 6 Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/club-car/villager-6/villager-6_owners-manual_2626713043.webp)
Battery Charger, IQ Plus – Electric Vehicle
1
3
2
1. Level Indicator 2. Cap 3. Plates
Maintain electrolyte level from at least 1/2 inch (13 mm) above
plates to 1/4 inch (6 mm) below level indicator.
17
Figure 16
Electric Battery Electrolyte Level
BATTERY CHARGER, IQ PLUS – ELECTRIC VEHICLE
See General Warnings on page 11.
DANGER
• The charging area must be ventilated. Hydrogen level in the air must never exceed 2%. The total
volume of air in the charging area must be changed at least five times per hour. Exhaust fans should
be located at the highest point of the roof. Contact a local HVAC engineer.
• Do not charge the vehicle batteries with the vehicle covered or enclosed. Any enclosure or cover
should be removed or unzipped and pulled back when batteries are being charged. An accumulation
of hydrogen gas can result in an explosion.
WARNING
• Only trained technicians should repair or service the charger. Contact a Club Car distributor/dealer.
• Each charger should have its own dedicated 15 or 20 ampere separately protected (circuit breaker or
fuse) single phase branch circuit, in accordance with all applicable electrical codes for the location.
• Have worn, cut, or damaged power cords or wires replaced immediately.
• Do not connect a stationary charger to the receptacle if the charger cord, plug, or the vehicle
receptacle is broken, damaged, or does not make a good electrical connection. Fire or personal injury
can result. Have a qualified technician repair or replace it immediately.
• Be sure that all wire connections at the receptacle and fuse link are clean and tight.
• Do not expose to rain or any liquid. Keep the charger dry.
WARNING CONTINUED ON NEXT PAGE
Villager 6 and 8 Owner’s Manual
Page 41