TROUBLESHOOTING AND ELECTRICAL
SYSTEM: PEDAL-START GAS VEHICLE
Test Procedures
18
TEST PROCEDURE 14 – Kill Limit Switch – Pedal-Start Vehicles Only
See General Warnings on page 1-1.
NOTE:
This is a continuity test.
The kill limit switch is the lower of the two limit switches located in the electrical component box. There is a white/black
wire and a blue wire connected to this limit switch.
1.
If necessary, see Testing Basics on page 18-15.
2.
Disconnect battery and spark plug wire(s).
See Disconnecting the Battery-Gasoline Vehicles on page 1-5.
3.
Remove the electrical component box cover.
4.
Check for proper wiring and tight connections.
See Wiring Diagrams on page 18-8.
5.
Disconnect the wires from the lower of the two limit switches and test the limit switch for continuity.
– Place the red (+) probe of the multimeter on the common (COM) terminal (white/black wire) of the limit switch.
Place the black (–) probe on the normally open (NO) terminal (blue wire) of the limit switch. Without the lever
pressed, the reading should be no continuity. Press the lever, and the reading should be continuity. If either
reading is incorrect, replace the limit switch
.
6.
Reconnect wires to limit switch.
NO
COM
2m
20
m
200
m
2k
200
200
200
200
20
2
200
m
500
20k
200k
2000
k
1000
OFF
WAVETEK
5XL
V
V
V
A
!
!
COM
200nA
MAX
1000 ---
750V
FUSED
1
2
1. 200 Ohm Setting 2. Lever Up
476
Figure 18-17
Kill Limit Switch Test
2017 Carryall 500 and 700 Maintenance and Service Manual
Page 18-33
Содержание Carryall 500
Страница 2: ......
Страница 16: ......
Страница 120: ...8 Tires WHEELS AND TIRES Figure 8 2 Inflate Tire Page 8 4 2017 Carryall 500 and 700 Maintenance and Service Manual ...
Страница 452: ...NOTES ...
Страница 453: ...NOTES ...
Страница 454: ...NOTES ...
Страница 455: ......
Страница 456: ......