13
Starter/Generator
ELECTRICAL COMPONENTS: KEY-START WITH
NEUTRAL REV GAS VEHICLE
FIELD COIL REMOVAL
1.
Remove the retaining nut from each field coil terminal and slide the insulator out of the slots in the housing.
Remove the four pole piece screws from the housing. Remove the four pole pieces from inside the housing.
Remove the field coils from the inside of the housing
.
See following NOTE.
NOTE:
Do not remove the insulators or the field coils unless an electrical test indicates that it is necessary
.
See Test Procedure 8 – Starter/Generator (Starter Function) on page 11-17.
1
2
4
3
5
6
2
5
7
1. Press Ram 2. Wedge Attachment Tool 3. Bearing is sectioned for clarity. 4. Support inner race of bearing. 5. Use a 1/2 inch (12mm) socket
or pipe. 6. Press against armature shaft. 7. Bearing Puller Tool
494
Figure 13-9
Bearing Removal
7
2
2
5
4
3
1
6
7
1. Pole Piece 2. Pole Piece Screw 3. Retaining Nut 4. Insulator 5. Field Coil Terminal 6. Housing 7. Field Coil
495
Figure 13-10
Field Coil Removal