Single Point Watering System (SPWS)
Page 42
2007 Precedent Golf Car Owner’s Manual
SINGLE POINT WATERING SYSTEM (SPWS)
CAUT ION
• Water the batteries only AFTER charging.
• Use only the equipment provided in the Club Car SPWS Refill Kit (CCI P/N 102958001) to water
batteries with the SPWS.
WATERING BATTERIES WITH THE SPWS
Checking the Water Flow Rate
1. Connect the water hose with the built-in screen filter to the water faucet
.
See following
CAUTION.
CAUT ION
• Make sure the screen filter is clean.
• Do not use a longer garden hose than provided with the System (20 feet), as a decrease in
water pressure could overfill the batteries and damage the refill system.
2. Before screwing the hose-end assembly onto the opposite end of the water hose, check the screen filter
inside the end of the assembly to make sure it is clean
.
3. Connect the purger to the female coupler on the hose-end assembly
4. Completely open the water faucet until the water flows out of the hose-end assembly, and note the move-
ment of the red flow indicator balls.
See following NOTE
.
NOTE: The water flow rate must be at least two gallons-per-minute for the SPWS to function properly.
This step also eliminates any trapped air from the water hose.
5. After ensuring adequate water flow rate, press the grey button on the end of the female coupler to dis-
connect the purger from the pressure regulator.
Figure 29 Connecting Hose with Filter
to Water Source
Figure 30 Checking the Water Flow Rate
3
2
4
5
1
5
7
6
8
3