4.4 The electrical installation Must be carried out by a qualified                                                          

       electrician Following strict standards.

4.5 Be sure that the earth cable connection is correctly made.

4.6 Wires serving as equipotential bonding conductors shall have a                                    

       cross section area between 2.5mm and 6mm.

4.7 After the unit has been wired up turn on the power and press            

       the reset button of the GFCI, (Ground Fault Circuit Interrupter)          

       the GFCI works and cut the power, Then repress the reset button

       on the GFCI to reconnect the power. If the above operations do  

       not work check the GFCI connections, turn off the power supply  

       until the problem is solved and “RESET” Appears.

CAUTION

: In order to avoid a hazard due to inadvertent resetting of 

the thermal cut out, this Pond heater must NOT be powered 

through an external switching device, such as a timer, Or connected 

to a power supply circuit that is regularly switched 

ON and OFF.

-4-

-5-

Edition: 2017-09   a

9.

Technical Data

10. 

Heater Dimension

Fig.1

  

   

2000     

2000   

  

9080   

  

Power

  (Wattage)

1000       1000       4540   

   

Model

Pond water 

  Volume

Gallon    Litre

A

Model

Fig. 2

Fig. 3

130

210

30

30

Solvent Glue

32 or

 

33.5

48.5 or

 

50

1

5

6

207

202

130

120

94

1

4

8

.5

 A

5. 

Controls and Operations

  5.1 Due to the safety flow switch that is installed on this unit, the  

         heating elements will not operate unless the correct amount of    

         flow is being pumped passed the flow switch. (A minimum of  

          4000Lph of water is needed to trigger this switch). 

  5.2 Reset Button is depressed inside the thermostat during normal  

         operation (

Fig4

         Should for any reason the reset button pop out and cut the             

         power supply. The thermostat will have to be manually reset, 

         After firstly trouble shooting any faults if in any doubt always  

         consult with a qualified person.

   

The minimum continual operating flow rate 4000Lph is needed to 

operate heater.

  

6. 

Controls Prior To Initial Start-Up

  6.1 Check the direction of flow of water is set to same direction as is  

         indicated by a directional arrow on the side of heater unit.

  6.2 Check that the mains voltage and frequency are in Accordance  

         with what’s on  the model ID Plate. (

Fig.5

)

  6.3 After you have finished installing your Heater it will be  

          

         necessary to check there are no leaks at any of the joins or           

         connections do this by turning on your system pump and allow  

         the pump to run for 30-60 minutes without turning on the heater  

         at this point to ensure that there are no leaks this will also allow all  

         trapped air to be expelled from the heater this will to avoid any     

         unwanted hot spots inside the heat exchange chamber.

7. 

Start Up

         Turn the pump and heater on 

Only!

 when inlet and outlet pipes  

         are connected to the corresponding feed and return pipes.

8. 

Maintenance, Cleaning and Storage

  8.1 The Cloverleaf Pond Heater does not require any special 

         maintenance or programming, If the heater is to be left idle for a   

         period of time. We would be recommend to disconnected and     

         Clean and dry the heater before storage,Store in a dry well       

         ventilated place. 

  8.2 If any reason the mains power lead gets damaged it must be  

         replaced by a qualified electrician.

CL-PH1kW

CL-PH2kW

CL-PH1kW

CL-PH2kW

Pond Heater

Operating Instructions

IMPORTANT : Notice Please Read 

Before Installing and Turning on !

Fig. 5

Models

 

CL-PH1kW

CL-PH2kW

Fig. 6

Min - Water Level

TM

Cloverleaf

Simply the Best

 

30