1. 

General

 

This heater is especially for use on Ponds. 

it is very simple to install and use the Heater, But the basic safety 

Precautions should always be followed.

2. 

Installation

         The Pond Heater should be connected to the outlet of the pond 

         pump making sure the water is flowing in the direction shown on 

         the Pond Heater. This Heater must be installed horizontally. 

         Dimensions and of the pond heater Refer to (

Fig.1

)

3.  

Heater installation

 (

Fig.3

)

         Separate the connection nut, And join the feed pipe to the heater

         making sure the Sealing ring is in the correct position and screw 

         up the compression nut (make sure not to over tighten). 

         Loop pipework to perventing Heater unit from draining (

Fig.6

).

4. 

Electrical Connection

  4.1 The electrical installation should have an all poles disconnection

         System with contact opening at least 3mm.

  4.2 For continued protection against possible electric shock this

         Pond Heater unit is to be mounted in accordance with 

         the instillation instructions. 

 4.3 For the protection of the system this heating unit  should be wired 

        on to a Residual Current device (RCD) with a rated tripping current 

        not exceeding 30mA. The supply cable should comply with EMC 

        standards.

!

This item must not be disposed of into the domestic 

waste. Please ensure it is disposed in an authorized place 

for recycling of with electrical and electronic appliances.

Resources, And make sure the product is disposed in an 

environmental friendly  way.

Cloverleaf

Pond Heater

Operating Instructions

IMPORTANT : Notice Please Read 

Before Installing and Power on !

1.         DANGER :RISK OF ELECTRIC SHOCK
Connect only to a circuit protected by a RCD Unit.
2. Grounding is required.
3. This product must be installed by a qualified electrician.
4. Do not cover the heater when in use.
5. When using for the first time , Ensure all pipe work is full of water 
and primed before turning the power on.
7. Children should be supervised to ensure not to adjust 
the heater settings.
8. Do not switch on if there is a possibility that water inside
 the heater is not frozen
9. IP45 Rated
10. Save these instructions.

4.4 The electrical installation Must be carried out by a qualified                                                          

       electrician Following strict standards.

4.5 Be sure that the earth cable connection is correctly made.

4.6 Wires serving as equipotential bonding conductors shall have a                                    

       cross section area between 2.5mm and 6mm.

4.7 After the unit has been wired up turn on the power and press            

       the reset button of the GFCI, (Ground Fault Circuit Interrupter)          

       the GFCI works and cut the power, Then repress the reset button

       on the GFCI to reconnect the power. If the above operations do  

       not work check the GFCI connections, turn off the power supply  

       until the problem is solved and “RESET” Appears.

CAUTION

: In order to avoid a hazard due to inadvertent resetting of 

the thermal cut out, this Pond heater must NOT be powered 

through an external switching device, such as a timer, Or connected 

to a power supply circuit that is regularly switched 

ON and OFF.

W

ARNING

     !

    Thermal cut-out

(Manually resettable)

Located under

screw cap.

Fig.4

www.cloverleaf.uk.net

Cloverleaf Industries Ltd

King Street, High Ongar, Essex, CM5 9NP

t:+44(0)1277366002/ f: +44(0)1277366004

e: [email protected]