Cloud Matrix 4 Скачать руководство пользователя страница 4

Matrix 4 I

NSTALLATION AND OPERATION MANUAL

  

 

For balanced microphones, connect the cable screen to pin 1, the in-phase signal (+) to pin 2 
and the reverse phase signal (-) to pin 3.  

 

For unbalanced microphones, connect a wire link from pin 1 to pin 3 inside the XLR type 
cable mounted plug; use pin 1 as ground (cable screen) and pin 2 as hot.  

 

Phantom power facilities are provided; any one of the four inputs can be configured to 
operate with 15V phantom power by positioning the relevant jumper as detailed below: 

 

Phantom Power Jumper Locations 

MIC  1  PHANTOM  POWER

MIC  2  PHANTOM  POWER

MIC  3  PHANTOM  POWER

MIC  4  PHANTOM  POWER

PAGING  MIC PHANTOM

POWER

OFF

ON

MIC 1

INPUT

MIC 2

INPUT

MIC 3

INPUT

MIC 4

INPUT

PAGING

MIC

INPUT

 

When setting the jumpers please ensure that you: 

• 

Remove the mains cable from the rear of the product before removing the top panel. 

• 

Only reassemble the unit using screws identical to the original parts. 

• 

Only use a microphone that requires phantom power.

  

 

6 Microphone 

Sensitivity 

The microphone amplifier has a fixed gain of 40dB with an additional post level control gain 
of 20dB.  The total gain of 60dB is adequate for all speech applications and maintains a high 
overload margin, however, it is important to operate the unit with the mic level control 
positioned at or above the 12 o’clock position. 
If the microphone signal is derived from a line level device such as a radio microphone the 
input amplifier can be configured to operate with a gain of 0dB (+20dB overall gain); by 
configuring the relevant PCB mounted jumper.  The Jumpers are marked as J1,J2,J3&J4 
and are associated with the microphone inputs as follows: 

 

J1

 = Mic Input 1 

J2

 = Mic Input 2 

J3

 = Mic Input 3 

J4

 = Mic Input 4 

 

A diagram showing the location of J1,2,3&4 can be found on the following page. 

 

16/12/02 V6.0 

Содержание Matrix 4

Страница 1: ...Matrix 4 Installation User GuideV 6 0 Cloud Electronics Limited 140 Staniforth Road Sheffield S9 3HF England Tel 44 0 114 244 7051 Fax 44 0 114 242 5462...

Страница 2: ...Filter 4 9 Microphone Level Controls 5 10 Microphone Routing Switches 5 11 Master Microphone Level Controls 5 12 Microphone Priority 5 13 CPM 4 Paging Microphone 5 14 Paging Microphone Channel 6 15 P...

Страница 3: ...e required to feed up to four separate areas with full user control of the signal routing The CPM 4 four zone paging microphone is available as an accessory to the Matrix 4 See section 13 for more det...

Страница 4: ...e rear of the product before removing the top panel Only reassemble the unit using screws identical to the original parts Only use a microphone that requires phantom power 6 Microphone Sensitivity The...

Страница 5: ...mised for the tonal correction of speech signals and the HF Treble control provides 10dB at 5kHz with the LF Bass control 10dB at 100Hz A flat frequency response is achieved with the adjustment slots...

Страница 6: ...ity over all microphone and music signals When a paging announcement is detected on any of the four zones all other microphone signals are fully muted and any music signal present will be reduced by 3...

Страница 7: ...hen the 9 pin connector is not connected to a CPM 4 zone control reverts to the front panel routing switches Phantom power is available 15V on the paging mic input and can be activated by configuring...

Страница 8: ...l control and adjacent music source select switch allowing selection and control of either line 1 or line 2 In addition to this each of the four zones has a set of two band music equalisation controls...

Страница 9: ...ty Considerations and Information The unit must be earthed Ensure that the mains power supply provides an effective earth connection using a three wire termination When the mains switch is in the off...

Отзывы: