background image

C l e a r l y   b e t t e r   s o u n d

Required Skill Level:  

Low. 

Ability  to  strip  wire  neatly,  crimp  RJ45  connectors, 

and use of crimp ferrules. 

Tools required: 

RJ45  crimp  tool,  small  wire  cutters,  wire  stripper, 

small screwdriver, ferrule crimp tool. A drill will also 

be required if an enclosure is being used.

Procedure - wiring:

The procedure essentially consists of “breaking-out” 
three cores of Cat 5 cable and wiring them to one 

of the Z4/8

MK4

’s four balanced line inputs. A terminal 

block housed in a plastic enclosure is used to make a 

neat and mechanically robust set of connections.

Follow the wiring instructions in the LM-2 Installation 
Guide, and install screened Cat 5 cable between the 

host unit and the LM-2. Crimp a shielded RJ45 onto 
each end of the cable according to the normal wiring 
standard, which is included here for completeness:

At  the  LM-2  end,  plug  the  RJ45  into  the  LM-2’s 

OUTPUT connector.

Turn the host unit off, plug the RJ45 into the Facility 
Port for the Zone in use, then cut the Cat 5 cable 
approximately 15 cm (6”) back from the connector. 
Strip  the  jacket  back  on  both  ends  by  about  5  cm 
(2”), fit H15 sleeves, and fan the cores out, including 
the drain wire for the cable screen.

If  the  terminal  block  is  to  be  housed  in  a  plastic 
container  (recommended  for  neatness),  pass 

the  cables  through  holes  in  the  enclosure,  fitting 

grommets in the holes first.  (The holes may need to 
be drilled.)

FROM LM-2 IN

REMOTE LOCATION

TO FACILITY PORT

ON HOST UNIT

Screened Cat 5 cable

Plastic enclosure with

 

grommetted entry holes

As Cat 5 cores are invariably solid wires, it is strongly 
recommended  that  crimp  ferrules  are  fitted  to  all 
cores  to  make  a  mechanically  robust  connection. 
White  ferrules  should  be  satisfactory  for  all  the 
connections.

Connect the cores into the terminal block as shown:

WT/OR

OR

WT/GN

GN

BL

WT/BL

WT/BN

BN

SCN

WT/OR

OR

WT/GN

GN

BL

WT/BL

WT/BN

BN

SCN

hot (‘+’)

cold (‘-’)

Cat 5 to Facility Port

Cat 5 from LM-2

1

3

2

Z4/Z8 Balanced Line Input

hot (‘+’)

cold (‘-’)

Note: Do not connect RJ45 

Pins 1, 2 or 3 (Wt/Gn, Or & Wt/Or) 

Twin-and-Screen

Audio Cable 

9-way Terminal Block

Note that the White+Green core (RJ45 pin 3) should 
not be connected in this particular application. This 
core carries the VCA priority control voltage from 

PIN

USE

CAT 5 CORE

1

Audio ‘cold’ phase (-)

White + Orange

2

Audio ‘hot’ phase (+)

Orange

3

Priority VCA control

White + Green

4

+V

Blue

5

0 V

White + Blue

6

-V

Green

7

Music level control (0 to 10 V)

White + Brown

8

Music source select control (0 to 10 V)

Brown

SCN

GND for system music controls

Connector shell

1

8

1

8

1

8