6.01 Equalisation 

 

Both Zone 1 and Zone 2 have separate treble and bass controls for the music signals and 
the microphone signals. These pre-set controls are protected by the front panel mounted 
anti-tamper panel. The music treble control has a range of ±10dB at 10kHz and the music 
bass control operates with a range of ±10dB at 50Hz. The microphone tone controls 
operate at ±10dB at the frequencies of 8kHz and 100Hz. 

 
 

6.02 Switch-on 

Mute 

 

When the CX242 is switched on, a two stage mute circuit operates. The music signals are 
fully muted for a period of two seconds, followed by a five second period when the music 
level smoothly changes to the level set by the controls. During this switch-on mute cycle, 
the red 'Music Mute' LED will illuminate. 

 
 

6.03  Remote Control Requirements 

 

The CX242 is fitted with VCA control of the music level as standard but if remote control 
of the signal source and level is required, then the optional 'Remote Source/Level Plate' 
(RSL-1) is required. Both Zone 1 and Zone 2 can be operated remotely or by local control 
as required. 
The RSL-1 can be fitted directly onto a standard UK electrical single gang mounting box 
(recessed or surface) with a minimum depth of 25mm (not supplied). Two core screened 
cable must be used to link the remote plate to the CX242. Connect the cable screen to 
terminal 1 on both the mixer connector and the remote plate.  Terminals 2 & 3 on the 
mixer connector should connect to terminals 2 & 3 respectively on the remote plate. 
When the mono mode is selected and the front panel source select switch is used, a 
remote plate with a level control only is available (RLC- 1) for installations where separate 
control of the mono signal present on the right output socket is required.  Single screened 
cable can be used for the RL-1, connect the screen to terminal 1 and the core to terminal 
2, with no connection to terminal 3. 
 
 

Remote Music Mute - Fire Alarm Interface 

 
In certain circumstances, there may be a Local Authority or Fire Service requirement to 
mute the music signals via a fire alarm control panel in an alarm condition. The CX242 
provides a facility to attenuate the music signals only, by using a fully isolated pair of 
contacts (usually a relay mounted close to the CX242 which is powered by the fire alarm 
control panel) which should close during an alarm condition. 
In the mute mode, a music gain reduction of between 20dB and 70dB (full mute) is 
effective and the desired mute level can be set by adjusting the small pre-set level control 
adjacent to the 2 pole remote music mute connector on the rear panel. The front panel 
mounted 'Music Mute' LED will illuminate to indicate the operation of the mute circuit. 

15/07/02 V4 

Содержание CX242

Страница 1: ...CX242 Zone Mixer Installation User Guide V4 0 Cloud Electronics Limited 140 Staniforth Road Sheffield S9 3HF England Tel 44 0 114 244 7051 Fax 44 0 114 242 5462...

Страница 2: ...crophone Inputs 6 5 01 Mic Inputs 6 5 02 Gain Control 6 5 03 Front Panel Level Controls 6 5 04 Microphone Priority 6 6 Zone Outputs 6 6 01 Equalisation 7 6 02 Switch on Mute 7 6 03 Remote Control Requ...

Страница 3: ...the moulded plug is cut off the lead for any reason the discarded plug is a potential hazard and should be disposed of in a responsible manner For more detailed information refer to the rear of the m...

Страница 4: ...se 7 Mic 1 priority on off in Zone 2 Button out off button in on 8 Mic 2 priority on off in Zone 2 Button out off button in on 9 Remote local control of Zone 1 music signals Button out local button in...

Страница 5: ...press the switch marked REM to select remote control operation of the desired zone see Figure 1 Self adhesive labels are provided to identify the signal source on the front panel 4 03 Priority When a...

Страница 6: ...ote mode of operation is selected the source select control on the remote plate is operative and the remote level control adjusts the signal level of the left output socket in this mode the front pane...

Страница 7: ...of their choice The microphone signals are routed directly to the respective output stage and are unaffected by the operation of the music controls The gain control on the rear panel should be set at...

Страница 8: ...creened cable must be used to link the remote plate to the CX242 Connect the cable screen to terminal 1 on both the mixer connector and the remote plate Terminals 2 3 on the mixer connector should con...

Страница 9: ...eft Pin 13 0V Pin 14 0V Pin 15 Mic 1 Installation of standard Expansion Connector Kit The kit comprises two 15 way D connector assemblies and a screened link cable Fit the cable assemblies as follows...

Страница 10: ...left with no connection The nominal output signal in this mode is 6dBu 387mV The input gain controls may require to be adjusted to provide the extra 6dB of gain 10 Controlling the music functions usi...

Страница 11: ...nd of the equipment providing the control voltages we suggest that all pieces of equipment be positioned in close proximity 11 Technical Specifications Stereo Line Inputs Frequency Response 20Hz 20kHz...

Страница 12: ...arthed Ensure that the mains power supply provides an effective earth connection using a three wire termination When the mains switch is in the off position the live and neutral conductors of the main...

Отзывы: