Technical data
Shutdown procedure
•
For normal isolation, the Closomat toilet can be
turned off using the integrated switch. To carry out
any servicing, the unit
MUST
be isolated at the
mains feed.
Bathroom/shower room
installations
•
The Closomat toilet must not be in direct line
with the shower spray. Some form of partition
between shower and the Closomat toilet is
advisable to prevent any water spraying directly
onto the equipment.
•
A shower should not be used in conjunction with
the Closomat toilet i.e. under no circumstances
must a user shower whilst seated on the
Closomat toilet.
Water services (WRAS approved)
•
It is essential that the entering water
is cold.
•
We would recommend water supply isolated via
isolation valve.
•
Water supply can be from storage vessel or mains
(‘Grey Water’
MUST NOT BE USED
).
•
Boiler Capacity: 1.7 litres.
•
Water rate: min. 8 l/min.
max. 0.8 MPa (8 bar)
•
Cistern capacity: 6 litres.
Overflow
•
The Closomat toilet has an internal overflow
which discharges into the W.C. pan through the
flush valve.
Soil connection
•
Relevant soil connector to be sourced by installer.
•
Soil connections suitable for Closomat toilet;
S-Trap (vertical fall) wall to centre of pipe from
70mm-230mm max. P-Trap (horizontal) floor to
centre of pipe 200mm max.
•
The Closomat toilet is suitable for all turned trap
outlets, through purpose made removable side
covers on lower level.
The Closomat toilet
MUST
be installed by a competent or
qualified person.
Explanation of symbols
•
Safety instructions in this manual are identified by
symbols. The safety instructions are introduced
by signal words, which express the extent of the
hazard/risk.
•
In order to prevent accidents, personal injury,
property damage and guarantee maximum user
safety, follow the safety instructions without fail
and exercise caution.
Description of equipment
•
The Closomat toilet is an electrically operated
shower (wash and dry) toilet designed to provide
the operator/user with a hygienic solution to toileting.
Start-up procedure
•
To enable a warm washing cycle operation
the Closomat toilet must be switched on.
Each Closomat toilet has its own isolation switch.
To switch the unit on, locate the switch on the
right hand side of the unit at the base of the
cistern cover, through a Perspex screen.
•
Once switched on, the water will reach core
temperature within 5 minutes. It is advised that to
maintain the core temperature in readiness for
use, the unit be left switched on at all times.
Electrical services
•
To avoid the risk of electric shock, this equipment
MUST
only be connected to a supply mains with
protective earthing by a competent or qualified
person.
Mains isolation
•
All electrical appliances must be installed in
accordance to the relevant regulations associated
with the country it is within. To conduct any form
of repairs or servicing it is recommended that
a mains isolation device be located in the vicinity
of the unit.
•
220-240V single phase AC supply is required,
(loading 4.5A-4.9A, maximum power 1300 watts).
The Closomat toilet is supplied with a 3 core cable
attached and
MUST NOT
be removed or replaced.
A 10A fused spur is required for isolation.
•
Spur outlet to be located in accordance with
current I.E.E. Regulations (Current Edition).
•
No modification of this unit is allowed other than
by the manufacturer.
•
Closomat has IPX4 rating.