background image

WARNING: 

Installation and operation of electronic and high pressure systems (fluids and 

compressed gas) involves risk including property damage and personal injury or death. 
Users should be properly trained or certified and take safety precautions. 

EVPD PROPORTIONAL VALVE DRIVER

Installation & Operations Manual

Section 1 Wiring

Step 3:

 

Connect Valve to Valve + and Valve - 

Terminals

 

(Valve is not polarity sensitive.)

Step 2:

 

Configure Jumper 2 Based on Valve

Step 1:

 

Configure Jumper 1 Based on Command

Step 5:

 

Connect Power to +VDC and GND Terminals.

 

Power requirements are determined by valve 

voltage specification.  The table below shows the recommended input voltage range for each valve type.

Upon successful powering of the board, the Power 

LED (

red

) will become lit.

Current Max. (Imax)

Current Min. (Imin)

Command
Threshold (DB)

Status Indicator  

LED

Power 

LED

St

LED

tatu

St

D

Power (See Step 5)

Common (GND)

Valve +
Valve -

Voltage  Command

5V

Current  Command

0 to 100 mA
0 to 200 mA

0 to 400 mA

10V

Jumper 2 (J2)
EVPD Output

370 mA
185 mA

92 mA

Valve

Jumper 1 (J1)

1.56” 

(39.6 mm)

1.31” 

(33.3 mm)

1.00” (25.4 mm)

1.26” (32 mm)

0.104” 
dia.

      DVP/EVP 

J2 Jumper 

Board 

Valve Max.

    Valve Type 

Configuration 

Output 

Current*

  0 to 5 VDC 

 

 

 400 mA            370 mA

 0 to 10 VDC   

 

 

 200 mA            185 mA

 0 to 20 VDC** 

 

 

100 mA**           92 mA

 

* As per DVP or EVP specifications                ** Factory Jumper setting

      DVP/EVP 

J2 Jumper 

Board 

Valve Max.

    Valve Type Configuration Output  Current*

  0 to 5 VDC 

 

 

 400 mA            370 mA

 

 0 to 10 VDC   

 

 

 200 mA            185 mA

 

 0 to 20 VDC** 

 

 

100 mA**           92 mA

 

0 to 5 VDC or

Command 

0 to 20 mA or 

0 to 10 VDC*

       Type 

     4 to 20 mA                

       

         J1

     Jumper 

 

 

       

Configuration

*   Factory Jumper setting. PWM voltage must correspond to 

Power LED

  DVP/EVP 

Drive Supply 

 

Ideal Supply

  Valve Type 

Voltage Range 

 

Voltage

  0 to 5 VDC 

7 to 12 VDC 

 

12 VDC

 0 to 10 VDC 

12 to 28 VDC 

 

24 VDC

 0 to 20 VDC 

24 to 28 VDC 

 

28 VDC

Step 4:

 

Connect Command Source

Unused command input should be grounded to 

ensure proper operation of the driver. For PWM command, 

use voltage command terminal.

Wiring Configuration

Current Command Type              Voltage Command Type

Clippard DVP or 
EVP Series Valve

Δ

    Jumper selected voltage. 
    Caution: Do not exceed Command Input Range by more than  
    25% or permanent damage may occur to the driver.

877-245-6247  |

 

 

clippard.com

CLIPPARD INSTRUMENT LABORATORY, INC. • ISO 9001:2015