67
IT
ES
GB
GAS CONVERSION
Should it be necessary to conver t the
appliance to a different gas from the one
for which the boiler has been equipped,
approach the technical staff.
CLEANING AND
MAINTENANCE
Preventive maintenance and checking of
the efficient operation of the equipment
and safety devices must be carried out
exclusively by the authorized technical
staff. The boiler is supplied with an elec-
tric cable. Should this require replace-
ment, contact exclusively with the autho-
rized technical staff.
FAULTS FINDING
–
Ignition failure/safety stat
interception
(fig. 27)
If the burner fails to start the red led
that signals blockage will light up.
To attempt starting it again, the selector
knob must be turned to the position ( )
and released soon after, returning to the
summer (
) or winter (
) position.
If the failure should occur again, call
the authorised technical staff to check
the boiler.
–
Restoring pressure in the
heating system
(fig. 27/a)
Periodically check that the pressure in
the system is between 1 and 1.2 bar. If
the pressure is below 1 bar, restore by
means of the filling cock.
ONCE FILLED CLOSE THE FILLING TAP.
–
Other faults
(fig. 27/b)
If orange indicator light comes on (SM
probe fault), turn off the boiler and con-
tact your authorised technical service
centre.
- Version
“GG F 23 - 28 BF”
:
If the green flashing indicator light
comes on (fan fault/exhaust pressure
switch), turn off the boiler and contact
your authorised technical service cen-
tre.
If the flashing orange light comes on (no
water circulation), turn the boiler off
and then turn it on again to restore
functioning. If the indicator light comes
on again, turn off the boiler and request
assistance from an Authorised Techni-
cal Service Centre.
- Version
“GG F 23 - 28 OF”
:
If the green flashing indicator light
comes on (exhaust thermostat tripped),
to begin functioning again, reset the
exhaust thermostat button. If the device
is tripped frequently, contact your
authorised technical service centre.
If the flashing orange light comes on
(insufficient water pressure), restore
DIODE ROUGE
Fig. 27/a
Fig. 27
IT SPIES REDHEAD
Apre
OPEN