nozzle into the condensate 

container below either continuously 

or only during the defrosting 

phases. 

A float is installed inside the 

condensate container. In the event 

that the container is full, the float 

will activate a microswitch which 

will switch off dehumidification 

mode. 

The units switch off and the 

“container full” indicator light on 

the control panel illuminates. 

This extinguishes again when 

the empty condensate container 

is re-inserted.  

The units then restart. 

In unattended continuous operation 

with an external condensate 

connection, the condensate that 

occurs is drained continuously via 

a hose connection. The units then 

start.

In unattended continuous operation 

with an external condensate 

connection, the condensate that 

occurs is drained continuously via 

a hose connection. 

Recirculating fan

Condensate 
container

Condenser

Evaporator

Condensate trap

Compressor

Moist room air

Dehumidified

room air

Fig. 1

  

Schematic depiction of the workings of the air dehumidifier

7.0 Unit description

In dehumidification mode, one of 

the “Fan stage” indicator lights on 

the control panel illuminates.

The fan extracts the moist room air 

through the intake grill with filter, 

evaporator and the condenser 

behind.

Heat is removed from the room air 

on the cold 

evaporator

. The air is 

then cooled to below dew point.  

The water vapour contained in 

the room air is then deposited 

as condensate or rime on the 

evaporator fins.

On the 

condenser

 (heat exchanger), 

the cold and dehumidified air is 

warmed up again and discharged 

back into the room via the outlet 

grill with a temperature increase of 

around 5 - 10 °C above the room 

temperature.

The processed, dry air then re-mixes 

with the room air. 

Continuous circulation of the room 

air through the unit gradually 

reduces the relative humidity (% RH) 

in the room to the desired humidity 

level.

Depending on the room air 

temperature and the relative 

humidity, condensed water will drip 

into the condensate trap and then 

through the integrated discharge 

The units have been designed for 

universal and straightforward air 

dehumidification. 

Their compact dimensions allow the 

unit to be transported and set up 

with ease.

The units operate in accordance 

with the condensation principle and 

are equipped with a hermetically 

sealed refrigerant system, heat gas 

defrosting, low-noise and low-

maintenance fan and connection 

cable with plug.

The fully automatic control, the 

variable hygrostat, the condensate 

container with integrated overflow 

protection and the connection 

nozzle for condensate drainage 

guarantee fault-free continuous 

operation. 

The units conform to the 

fundamental health and safety 

requirements of the appropriate EU 

stipulations.

The units are dependable and offer 

ease of operation.

The units are used in all locations, 

where dry air s a must and where 

economic consequential damage 

(such as that caused by mould) 

must be prevented. 

The units may be used for the 

drying and dehumidification of 

areas such as:

   Living rooms, bedrooms, shower 

rooms or cellar rooms 

   Laundry rooms, weekend homes, 

caravans

   Warehouses, archives, 

laboratories 

   Bathrooms, wash rooms and 

changing rooms etc.

   Basements, storage rooms

Operating sequence

The units are switched on and off by 

the power key. 

Содержание CTK 240

Страница 1: ...CLIMIA CTK 240 mobile air dehumidifier Operating manual Edition 1 0 English ...

Страница 2: ......

Страница 3: ...ted for errors or misprints 1 0 Safety instructions 4 2 0 Environmental protection and recycling 4 3 0 Guarantee 4 4 0 Intended use 4 5 0 Transport and packaging 5 6 0 Air dehumidification 5 7 7 0 Unit description 8 8 0 Set up 9 9 0 Commissioning 9 12 10 0 Shutdown 12 11 0 Unit transport 12 12 0 Care and maintenance 13 14 13 0 Troubleshooting and customer service 14 14 0 Electrical wiring 15 15 0 ...

Страница 4: ...right water will escape otherwise Before each change of location the condensate container must be emptied All electrical cables on the outside of the units must be protected against damage e g by animals etc Before each change of location the condensate containers must be emptied Appropriate hazard prevention measures must be taken to prevent risks to people when performing installation repair mai...

Страница 5: ...r materials such as powdery substances packaging wood and electronic units Buildings may be dried in a variety of ways 1 By heating and air exchange The air in the room is heated in order for moisture to be removed and then this air is fed outside All of the energy that is involved is lost together with the moist air that is released 2 By air dehumidification The moist air that is present within a...

Страница 6: ...he temperature rises I e the maximum possible absolute water content becomes greater as the temperature rises Building materials and structures are capable of absorbing considerable volumes of water such as brick 90 190 l m heavy concrete 140 190 l m and limestone 180 270 l m The drying of moist materials such as masonry is effected as follows The moisture moves from the inside of the material to ...

Страница 7: ...ensation heat The Energy transferred to the air from the condenser consists of 1 The amount of heat derived beforehand in the evaporator 2 The electrical drive energy 3 The condensation heat released by liquefying the water vapour Energy must be supplied when liquid is converted into a gas This energy is designated as evaporation heat It does not cause any increase in temperature but is required t...

Страница 8: ...and discharged back into the room via the outlet grill with a temperature increase of around 5 10 C above the room temperature The processed dry air then re mixes with the room air Continuous circulation of the room air through the unit gradually reduces the relative humidity RH in the room to the desired humidity level Depending on the room air temperature and the relative humidity condensed wate...

Страница 9: ... up instructions Min 0 5 m distance to wall Maintain adequate clearance from heaters or other sources of heat Keep windows and doors closed Fig 2 Schematic depiction of how to set up the air dehumidifier 9 0 Commissioning Before commissioning the unit or if local requirements dictate the air inlet grill and air outlet grill must be checked for contamination Important notes prior to commissioning A...

Страница 10: ... of the unit can no longer be guaranteed NOTE After setting the required air humidity the display shows this for another 10 seconds before displaying the current air humidity again NOTE Note that the compressor does not switch on until a waiting time of 3 minutes has elapsed Restart protection Control panel The control panel contains various keys indicator lights and a display 7 The bucket full in...

Страница 11: ...r function Pressing the timer key switches the unit s automatic mode on and off If automatic mode is switched off the arrow keys can be used to set the required operating time The operating time can be set for a maximum of 24 hours in increments of an hour The unit will switch itself off automatically after the set time has elapsed NOTE If the room temperature is sufficiently high 12 C the surface...

Страница 12: ...e connection by hand In unattended permanent operating mode the condensate should preferably be drained into a lower level drain If using an external collection container pan bucket etc the unit must be placed at a correct height 10 0 Shutdown The units are equipped with four foot rollers and two additional handles for easy and convenient transport Before each change of location switch off the uni...

Страница 13: ... traps with hose connection the fan and the fan housing carefully Check all unit components for damage and repair if necessary Carefully refit all parts that were removed in reverse order NOTE Regular care and maintenance is fundamental to a long service life and fault free operation of the unit CAUTION Before undertaking any work on the units the power plug must be removed from the mains socket N...

Страница 14: ...the connection nozzles checked to see whether there are dirt deposits on them This work requires the unit to be opened and must therefore only be carried out by an authorised specialist company NOTE Heavily contaminated or damaged air filters must be replaced with new parts Only original spare parts may be used NOTE Adjustment and maintenance work may only be carried out by authorised and qualifie...

Страница 15: ... in fully unreeled or reeled off condition NOTE The electrical connection to the units must be made at feedpoints with residual current devices in accordance with VDE 0100 Section 704 When installing the units in extremely damp environments such as laundry rooms showers etc the unit must secured with a residual current device provided by the customer in accordance with the regulations 14 0 Electri...

Страница 16: ...iew of unit We reserve the right to modify the dimensions and design as part of the ongoing technical development process 2 1 4 3 5 6 7 8 10 11 12 37 3 32 31 30 26 47 45 44 43 41 39 38 49 50 51 9 46 40 42 16 33 21 13 23 24 22 ...

Страница 17: ...Capillary 12 Y pipe 13 Condenser for compressor complete 16 Microswitch 21 Condensate trap cover 22 Fan housing 23 Fan wheel 24 Fan motor 26 Distribution block 30 Control board 31 Conductor board board 32 Probe evaporator EVAP 33 Hygrostat 34 Condenser fan motor 37 Mains cable with plug 38 Front wall 39 Back wall 40 Transport handle 41 Top cover 42 Intake grill 43 Air filter 44 Condensate bucket c...

Страница 18: ... 27 C 60 RH l day 18 Fan stages 2 Max airflow volume m3 h 240 186 Condensate container capacity Litres 6 3 Refrigerant 1 R134A Refrigerant quantity g 200 Power supply V Hz 230 1 50 Max rated current consumption A 4 1 Max power consumption kW 0 57 Sound pressure level LpA 1m 2 dB A 46 41 Dimensions Depth mm 272 Width mm 384 Height mm 610 Weight kg 17 We reserve the right to modify the dimensions an...

Страница 19: ...r cleaned Fan function checked Air inlet grid with filter cleaned Unit checked for damage Safety devices checked All fastening screws checked Electrical safety check Test run 1 Date Signature 2 Date Signature 3 Date Signature 4 Date Signature 5 Date Signature 6 Date Signature 7 Date Signature 8 Date Signature 9 Date Signature 10 Date Signature 11 Date Signature 12 Date Signature 13 Date Signature ...

Страница 20: ... D 32758 Detmold Germany Name of the CE representative Intakt GmbH Climia Air conditioning and heating technology Niemeierstraße 13 D 32758 Detmold Germany Unit machinery model Air dehumidifier Series Class CLIMIA CTK 240 Series Class Number 1803 Delegated regulations EU 2011 65 EU 2011 2014 30 EU 2014 2014 35 EU 2014 Applicable standards DIN EN 12102 1 2018 DIN EN 55014 1 2017 DIN EN 55014 2 2015...

Страница 21: ...21 CTK 240 mobile air dehumidifier Notes ...

Страница 22: ...22 CLIMIA ...

Страница 23: ...23 CTK 240 mobile air dehumidifier ...

Страница 24: ...Intakt GmbH Climia Klima und Wärmetechnik Niemeierstraße 13 D 32758 Detmold ...

Отзывы: