Fig. 13: Inserting the sealing cover
7.
Plug in the power plug and switch the unit
back on.
Fig. 14: Switching the unit on
8.
After the filter has been replaced, the filter
change indicator still lights up. This must be
reset by pressing the key for at least 3
seconds
If the filter needs to be replaced before the
filter indicator lights up (e.g. after 8 months),
this must also be reset.
The unit must be switched off for this using
the “on/off” key. Press and hold the key for
3 seconds. The symbol lights up. Press and
hold the key again for 3 seconds until the
lighting goes out. The filter indicator is now
reset.
7
Filter cleaning
In order to increase the efficiency and service life
of the filter unit, we recommend cleaning the pre-
filter at intervals of 2 weeks.
Proceed as follows:
1.
Remove the filter unit (see chapter “Filter
change”)
2.
Use a H13 or H14 vacuum cleaner in order to
remove coarse dirt (dust, hair, etc.) of the
pre-filter.
Fig. 15: Removing the sealing cover
3.
Then vacuum out the device housing (air
inlet grill) and insert the filter again.
Fig. 16: Removing the filter unit
CLIMIA