All products subjected to fall arresting forces should be removed
from service immediately!
DECK/FLOOR/GROUND LEVEL
WORK SURFACE
(ANCHOR POINT)
MINIMUM CLEARANCE 3ft (1m)
W
A
RNING!!! SWING F
ALLS C
AN OC
CUR
WHEN
THE
W
ORKIER IS NO
T DIREC
TL
Y UNDER ANCHOR POINT
.
Free fall distance (limit) must
not exceed 6’ ft (1.8 m).
The Hollow Core
concrete must be
5000-psi or higher and
fully cured. Installation
location to be approved
by a qualified person.
Performance:
Static tensile strength:
5000-lbf
(
22kN) minimum.
Maximum capacity:
one worker with
max weight of
310-lbs when used as
a single point anchorage connector
for personal fall arrest or restraint
Dimensions:
Weight:
0.4-lbs (.18kg)
Length:
11.5” (293mm)
Diameter:
0.75” (20mm)
Regulatory compliance
ANSI Z
359.1-2007, ANSI Z359.7-2011 and OSHA
1926.502 CE 0321 / EN
795:1996 (+A1:2000) Class B
Component Materials:
Main Cable:
Aircraft Cable.
Ball Shank:
Stainless Steel.
Toggle Bar:
Stainless Steel.
Hole
Plug:
Aluminum.
Spring:
Zinc Plated Steel.
Swage:
Zinc Plated Copper.
Activator Wire:
Aircraft Cable.
Loop Cover:
Polyurethane.
WORK SURFACE
May be used as a anchoring point for a leading
edge restraint system. (Examples are of optional
anchoring point locations. The use of two anchors
is for illustration purposes only and not required
for leading edge restraint systems unless other-
wise specified by the manufacturer.
OPTIONAL
(ANCHOR POINTS)
Toggle Bar
Spring
Swage
Anchor Loop
1.5” (38mm)
3.0” (76mm)
10.75” (273mm)
Main Cable
2” (50.8mm)
Activator Wire
Hole Plug
.75”ø (20mm)
Ball Shank
INSTALLATION:
(1)
(2)
(3)
(4)
(5)
(6)
Drill
3/4”
(20mm)
Flip
Toggle
To
Vertical
Position
Insert
In
Hole
Push
Down
Pull
Up
INSTALLATION IN HOLLOW CORE CONCRETE:
(1) Drill a 3/4” (20mm) hole in center of the hollow channel in the
hollow core concrete. The hollow core concrete must be at least
5,000-psi (34.5 MPa) concrete with a web thickness of 1-3/4”
(44.45mm) thick. Works with 6“ hollow core or larger.
(2) Never drill any hole closer than 6” (152mm) to any edge or
corner.
(3) Always inspect the hole carefully when reusing a previously
drilled hole.
(4) Make sure the toggle bar is fully seated and in lock position.
(See activation indicator illistration)
(5) The hole plug should be full seated in the drilled hole in the
concrete.
INSTALLATION IN STEEL:
(1) Drill a 3/4” (20mm) hole in the steel flange. Steel flange must
be at least 1/4” (64mm) thick.
(2) Never drill a hole closer than 1-1/2” (38mm) to any edge or
corner.
(3) When reusing a previously drilled hold always inspect the hole
carefully.
(4) Make sure the toggle bar is fully seated and in lock position.
(See activation indicator illistration)
Location of installation of the toggle anchor must be approved by a
Engineer or other qualified person to be compatible with any and all
structural & operational characteristics of the selected installation location.
WARNING!!!
LOCKED
POSITION
OPEN
POSITION
BL
A
CK RED
BL
A
CK RED
Activator
Wire
Indicator
OPEN
BL
A
CK RED
Activator
Wire
Indicator
NOT
SAFE
Activator
Wire
Indicator
ACTIVATION INDICATOR:
OPEN
OPEN
1-3/4”
min web
thickness
V1.1
REMOVAL INSTRUCTIONS:
(1) When removing anchor, place your thumb inside the anchor loop
and your first two fingers around the hole plug. Squeeze fingers and
thumb together till the trigger and spring fully compress.
(2) While squeezing the hole plug and loop pull the anchor out of the
hole.
DO NOT REMOVE
WARNING LABEL!
DO NOT REMOV
E
St
ainle
ss
S
te
el, Aluminum
, Zinc
Pla
te
d Copper
, 7
x1
9
A
ir
c
ra
ft
Ca
bl
e
Compli
a
nc
e:
O
SHA
19
26
.50
2 &
19
10
.6
6 /
ANSI Z35
9
.1
CE 0
32
1 / EN
7
95
:19
9
6
(
+
A
1:
20
0
0
) Cla
s
s B
W
ARN
IN
G!!!
AL
L
P
ER
SO
N
S U
SIN
G
TH
IS E
Q
UIP
M
EN
T MU
ST
R
EAD
AN
D
U
N
D
ER
ST
A
N
D A
LL
IN
STR
UC
TI
O
N
S.
FA
IL
U
R
E
TO
DO
SO
M
AY
R
ES
U
LT
IN
SE
R
IO
U
S
IN
JU
R
Y O
R
D
EA
TH
. U
SER
S SHO
U
LD
B
E F
A
M
IL
IA
R
W
IT
H P
ER
TIN
EN
T R
EG
U
LA
TI
O
N
S G
O
V
ER
N
IN
G
T
HIS
E
Q
U
IP
M
EN
T. AL
L IN
DI
V
ID
U
AL
S
W
HO
U
SE
TH
IS P
R
O
D
U
CT
MU
ST
B
E
P
R
O
P
ER
LY
IN
ST
R
U
CTED O
N
H
O
W
TO
U
SE
TH
IS
D
EV
IC
E.
RTL-
XXX / MM/Y
YYY
DO NOT REMOVE
T
oggle Bolt
Anchor
Model: TLA075N
1-(888)-206-1318
Stainless Steel, Aluminum, Zinc Plated Copper, 7x19 Aircraft Cable
Compliance: OSHA 1926.502 & 1910.66 / ANSI Z359.1, ANSI Z359.7
CE 0321 / EN 795:1996 (+A1:2000) Class B
WARNING!!!
ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS.
FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH. USERS SHOULD BE FAMILIAR
WITH PERTINENT REGULATIONS GOVERNING THIS EQUIPMENT. ALL INDIVIDUALS WHO USE
THIS PRODUCT MUST BE PROPERLY INSTRUCTED ON HOW TO USE THIS DEVICE.
RTL-xxx / mm/yyyy
INSPEC
T BEFORE USE
Max Capacity 310-lbs