4. Double coincidence configuration
1)
In the menu "panel
security“ set the timer for the cross zones to 1
minute or more (time within which the 2 zones must be activated to
trigger the smoke generator)
Страница 1: ...Configuration manual of the VESTA 156 1 Learning I O module on the panel 2 Module settings 3 Configuration activation rule 4 Double coincidence configuration ...
Страница 2: ...FIRST OF ALL Connect the battery of the I O module Connect the smoke generator in the terminals smoke only AFTER made the tests of working ...
Страница 3: ...odule on the panel 1 Activate the learning function on the panel for further info refer to the panel manual 2 Press the button on the I O module installed inside the VESTA 156 3 Select the detected device and press OK ...
Страница 4: ...e appropriate area to the input device DI and choose the zone number and the name of the device 5 Assign the same area to the output device DO and choose the zone number and the device name NB The device needs 2 zones SMOKE TAMPER SMOKE ACTIVATION ...
Страница 5: ...2 Module settings 1 The output module DO must be set as Separate devices 2 Set the input module as a tamper of the smoke generator ...
Страница 6: ...3 Configuration activation rule 1 In the menu automation rule create a new rule as indicated below ...
Страница 7: ...uration 1 In the device settings set at least 2 devices with the Cross zone attribute to activate the smoke generator ONLY in the event of the activation of both devices in a programmable time and thus avoid improper activations ...
Страница 8: ...4 Double coincidence configuration 1 In the menu panel security set the timer for the cross zones to 1 minute or more time within which the 2 zones must be activated to trigger the smoke generator ...