background image

 

ZigBee routers to improve signal strength. 

DO NOT 

use a ZigBee Router without backup battery. A 

ZigBee router without battery will be powered down during AC power failure and the Smoke 
Detector connected to the router will lose connection with ZigBee network. You should plan your 
Smoke Detector installation location using only ZigBee router with backup battery. 

 

Maintenance  

The top cover and the smoke detecting chamber can be detached from the Smoke Detector for 
maintenance. Follow the steps below to maintain the smoke detecting chamber: 

1. 

Remove the top cover by rotating the top cover counter-clockwise, then remove the smoke 
detecting chamber

 

               

                   

 

 

2. 

Pull out the anti-insect mesh inside the chamber and clean the chamber and mesh with a brush or 
water.

 

3. 

Re-insert the anti-insect mesh into the chamber and insert the chamber back onto the Smoke 
Detector. Please make sure the chamber is dry before re-inserting back onto the Smoke Detector.

 

 

 

4. 

Insert the top cover back onto the Smoke Detector. The top cover includes 3 insertion hooks to fit 
into the Smoke Detector. Each hook has a number next to it. Match these numbers with the 
numbers of insertion holes on the Smoke Detector.

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

Appendix 

(For developers only)

 

 

Smoke Detector Cluster ID 

Содержание SD-16-ZBS

Страница 1: ...ctor includes following models the models differ in battery used SD 16ZBS SD 16SL ZBS Parts Identification 1 Red LED Continuous quick flashes The Smoke Detector is alarming Two quick flashes The Smoke...

Страница 2: ...Smoke Detector will perform auto calibration after 4 hours After the first auto calibration the Smoke Detector will perform auto calibration every month During the auto calibration process the Smoke D...

Страница 3: ...ation is detected Please follow the steps bellow to join the Smoke Detector into ZigBee network 1 Insert the batteries into the battery compartment to power on the Smoke Detector 2 The Smoke Detector...

Страница 4: ...center of the ceiling or top of stairwell with at least 60 cm of space between the Smoke Detector and the wall Do not install the Smoke Detector in the following locations The Kitchen Smoke from cook...

Страница 5: ...smoke detecting chamber 1 Remove the top cover by rotating the top cover counter clockwise then remove the smoke detecting chamber 2 Pull out the anti insect mesh inside the chamber and clean the cham...

Страница 6: ...O 0x0011 PhysicalEnvironment 8 bit 0x00 0xff Read Write 0x00 O 0x0012 DeviceEnabled Boolean 0x00 0x01 Read Write 0x01 M Attribute of Identify Cluster Information Identifier Name Type Range Access Def...

Страница 7: ...fications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment Example use only shielded interface cables when connecting to compute...

Отзывы: