background image

 

Smoke Detector   
SD-16-ZBS / SD-16SL-ZBS 

 

Introduction 

SD-16(SL)-ZBS is a ZigBee Smoke Detector. It is capable of sending wireless signals to the coordinator 
in the ZigBee network upon detection of smoke particles. The Smoke Detector is designed to be 
mounted on ceiling or top of stairwells when smoke would concentrate to raise alarm timely and protect 
your home from fire hazards. 

The Smoke Detector utilizes ZigBee technology for wireless signal transmission. ZigBee is a wireless 
communication protocol that is reliable and has low power consumption and high transmission efficiency. 
Based on IEEE802.15.4 standard, ZigBee allows a large amount of devices to be included in a network 
and coordinated for data exchange and signal transmission 

The Smoke Detector serves as an end device in the ZigBee network. It can be included in the ZigBee 
network to transmit signal upon activation, but cannot permit any other ZigBee device to join the network 
through the Smoke Detector.   
The SD-16 Series Smoke Detector includes following models, the models differ in battery used. 
SD-16ZBS 
SD-16SL-ZBS 

 

Parts Identification 

1. Red LED 

- Continuous quick flashes   

The Smoke Detector is alarming. 

- Two quick flashes   

The Smoke Detector has successfully joined a ZigBee network after 
factory reset. 

- Flashes once every 20 minutes: 

The Smoke Detector has lost connection to its current ZigBee 
network. 

- Flashes every 4 seconds: 

Battery Exhausted 

- Flashes every 2 seconds: 

The Smoke Detector is under warm-up and self-calibration process 

- Flashes every second: 

The Smoke Detector is in Alarm Silence mode. 

2. Amber LED 

- Flashes every 4 seconds: 

Battery Exhausted 

- Flashes every 5 seconds: 

Auto-calibration has failed. 

3. Function Button 

- Press the button once to send a supervision signal / test Smoke 

Detector 

- Press the button once during alarm to silence the alarm. 
- Press and hold the button for 10 seconds then release to reset the 

Smoke Detector. 

- Press and hold the button for 20 seconds then release to recalibrate 

the Smoke Detector. 

4. Buzzer 

5. 

Mounting Hole

 

The Hook of the Mounting Bracket can hook into this Mounting Hole.

 

6. 

Battery compartment

 

The battery used varies according to Smoke Detector model number. 

7. 

Battery Compartment Cover

 

Содержание SD-16-ZBS

Страница 1: ...ctor includes following models the models differ in battery used SD 16ZBS SD 16SL ZBS Parts Identification 1 Red LED Continuous quick flashes The Smoke Detector is alarming Two quick flashes The Smoke...

Страница 2: ...Smoke Detector will perform auto calibration after 4 hours After the first auto calibration the Smoke Detector will perform auto calibration every month During the auto calibration process the Smoke D...

Страница 3: ...ation is detected Please follow the steps bellow to join the Smoke Detector into ZigBee network 1 Insert the batteries into the battery compartment to power on the Smoke Detector 2 The Smoke Detector...

Страница 4: ...center of the ceiling or top of stairwell with at least 60 cm of space between the Smoke Detector and the wall Do not install the Smoke Detector in the following locations The Kitchen Smoke from cook...

Страница 5: ...smoke detecting chamber 1 Remove the top cover by rotating the top cover counter clockwise then remove the smoke detecting chamber 2 Pull out the anti insect mesh inside the chamber and clean the cham...

Страница 6: ...O 0x0011 PhysicalEnvironment 8 bit 0x00 0xff Read Write 0x00 O 0x0012 DeviceEnabled Boolean 0x00 0x01 Read Write 0x01 M Attribute of Identify Cluster Information Identifier Name Type Range Access Def...

Страница 7: ...fications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment Example use only shielded interface cables when connecting to compute...

Отзывы: