Climax OPDC-1 Скачать руководство пользователя страница 2

 

Hold the Learn / Test button area and gently pull up the front cover. Remove the old battery as shown in Figure 1, 
and then press the Learn / Test button 5-6 times to fully discharge. Insert a new battery and replace the cover, as 
shown in Figure 2.   

Figure 1 

Figure 2 

 

 

 

Test Mode 

The Optical Door Contact can be put into Test mode for 3 minutes by pressing the Test Button on the front cover 
once. During Test mode, the LED indicator will turn on upon triggering. Each press on the Test Button, the Optical 
Door Contact will transmit a test signal to the Control Panel for radio range test and resets the test mode back to the 
3-minute duration.

 

It will exit Test Mode automatically after the 3 minutes and returns to Normal Operation mode.

 

 

Getting Started 

 

Step 1: Use a flat-headed screwdriver to fit into the cover opening hole at the bottom.   

 

Step 2: Gently push the flat-headed screwdriver upwards and remove the top cover. 

 

Step 3: Insert the battery into the battery compartment. Please avoid staring directly at the Infrared Detection Area   

 

 

when in operation. 

Step 4: Put the Control Panel into learning mode, refer to Control Panel manual for detail. 

Step 5: Press the Test Button on the Optical Door Contact to send signal to the Control Panel. 

Step 6: If  the  Control  Panel  successfully  receives  the  signal,  the  Control  Panel  should  respond  (e.g.  emitting 

beeps). Refer to your Control Panel manual to complete the learning process. 

Step 7: After the Optical Door Contact is learnt-in, put the Control Panel into “

Walk Test

” mode. Hold the Optical 

Door Contact at the desired location, and press the Test button to confirm if this location is within signal 

range of the Control Panel.   

Step 8: When you are satisfied with the Optical Door Contact at the chosen location, proceed to installation. 

 

Mounting the Door Contact   

Find a suitable place to install the Door Contact. It is recommended to install the Optical Door 
Contact on the more stationary object (such as door frame or window frame). Please make sure 
the location is within signal range of the Control Panel before mounting. 

Step 1: The mounting surface should be clean, dry, and smooth. Clean the mounting surface 

with a suitable degreaser if needed.   

Step 2: Remove  the  protective  covering  from  one  side  of  the  double-sided  adhesive  pad. 

Apply  to  the  back  of  the  device  and  press  firmly  for  30  seconds  to  ensure  good 

contact. 

Step 3: Remove the other cover and firmly press the Optical Door Contact onto the desired 

location. Please avoid applying the adhesive pad on uneven surface or re-apply it. 

Step 4: Mark the location for the reflecting sticker. The reflecting sticker has to be applied on 

the 

opposite

 side of the Infrared Detection Area. The gap should be no more than 

3mm

 when the door/window is closed. 

Step  5:  Apply  the  reflecting  sticker.  Please  avoid  applying  the  reflecting  sticker  on 

uneven surface or re-apply it. 

<NOTE> 

 

Please DO NOT apply the adhesive pad on a surface with peeling or cracked 
paint, or on a rough surface. 

 

Please note the 3M adhesive tape cannot be reused.   

 

Please DO NOT expose the Infrared Detection Area to direct sunlight. 