2
Hold the Learn / Test button area and gently pull up the front cover. Remove the old battery as shown in Figure 1,
and then press the Learn / Test button 5-6 times to fully discharge. Insert a new battery and replace the cover, as
shown in Figure 2.
Figure 1
Figure 2
Test Mode
The Optical Door Contact can be put into Test mode for 3 minutes by pressing the Test Button on the front cover
once. During Test mode, the LED indicator will turn on upon triggering. Each press on the Test Button, the Optical
Door Contact will transmit a test signal to the Control Panel for radio range test and resets the test mode back to the
3-minute duration.
It will exit Test Mode automatically after the 3 minutes and returns to Normal Operation mode.
Getting Started
Step 1: Use a flat-headed screwdriver to fit into the cover opening hole at the bottom.
Step 2: Gently push the flat-headed screwdriver upwards and remove the top cover.
Step 3: Insert the battery into the battery compartment. Please avoid staring directly at the Infrared Detection Area
when in operation.
Step 4: Put the Control Panel into learning mode, refer to Control Panel manual for detail.
Step 5: Press the Test Button on the Optical Door Contact to send signal to the Control Panel.
Step 6: If the Control Panel successfully receives the signal, the Control Panel should respond (e.g. emitting
beeps). Refer to your Control Panel manual to complete the learning process.
Step 7: After the Optical Door Contact is learnt-in, put the Control Panel into “
Walk Test
” mode. Hold the Optical
Door Contact at the desired location, and press the Test button to confirm if this location is within signal
range of the Control Panel.
Step 8: When you are satisfied with the Optical Door Contact at the chosen location, proceed to installation.
Mounting the Door Contact
Find a suitable place to install the Door Contact. It is recommended to install the Optical Door
Contact on the more stationary object (such as door frame or window frame). Please make sure
the location is within signal range of the Control Panel before mounting.
Step 1: The mounting surface should be clean, dry, and smooth. Clean the mounting surface
with a suitable degreaser if needed.
Step 2: Remove the protective covering from one side of the double-sided adhesive pad.
Apply to the back of the device and press firmly for 30 seconds to ensure good
contact.
Step 3: Remove the other cover and firmly press the Optical Door Contact onto the desired
location. Please avoid applying the adhesive pad on uneven surface or re-apply it.
Step 4: Mark the location for the reflecting sticker. The reflecting sticker has to be applied on
the
opposite
side of the Infrared Detection Area. The gap should be no more than
3mm
when the door/window is closed.
Step 5: Apply the reflecting sticker. Please avoid applying the reflecting sticker on
uneven surface or re-apply it.
<NOTE>
Please DO NOT apply the adhesive pad on a surface with peeling or cracked
paint, or on a rough surface.
Please note the 3M adhesive tape cannot be reused.
Please DO NOT expose the Infrared Detection Area to direct sunlight.