Optical Door Contact (OPDC-1) User Manual 

The Optical Door Contact, integrating infrared sensor, monitors the opening/closing of specified devices (e.g. door or window). 
By using infrared detection technology, the OPDC can detect if the door or window is open or closed, without the need of an 
additional magnet. The OPDC will transmit alarm signals when it detects a change, and keep your home protected. 

The Optical Door Contact consists of a cover and base. The base contains all electronics and provides a means for fixing the 
device. An enclosed PCB tamper switch provides tamper protection against unauthorized device opening. 

 

Identifying the parts 

 

 

 

1. 

LED Indicator

2. 

Learn / Test Button   

- Press the Test button to transmit a learn code. 

- Press the Test button once to enter Test Mode for 3 minutes. 

3. 

Tamper   

4. 

Battery 

5. 

Infrared Detection Area 

6. 

Reflecting Sticker 

 

 

LED Indicator     

In Normal operation mode, the LED indicator remains off except in the following situations: 

 

When the Optical Door Contact’s tamper switch is triggered. 

 

Every time the Optical Door Contact is activated under Tamper or Low battery condition.

 

 

Every time the Door Contact is activated and transmitting the signal under the Test mode. 

 

Supervision     

 

The Optical Door Contact will automatically transmit Supervisory signals periodically to the Control Panel at 
random intervals of 30 to 50 minutes in Normal Operation Mode. 

 

If the Control Panel has not received the signal from the Optical Door Contact for a preset period time, the 
Control Panel will indicate that particular Door Contact is experiencing an out-of-signal problem. 

 

Tamper Switch   

 

It is designed to protect against unauthorized cover opening. When the tamper is triggered, the Optical Door 
Contact will emit a signal to the Control Panel for reporting, the LED will also light up.   

 

Battery 

The  Optical  Door  Contact  uses  one 

1.5V  AAA  Alkaline  battery

  as  its  power  source,  and  it  is  also  capable  of 

detecting  low  battery.  When  the  battery  is  low,  a  low  battery  signal  will  be  sent  to  the  Control  Panel  along  with 
regular  transmission.  The  LED  will  light  up  when  the  Door  Contact  is  activated  under  low  battery  status.  When 
battery is exhausted, the Optical Door Contact will stop all function and the LED will flash every 4 seconds. 

 