49
DTMF
CHARACTER
COMMANDS
DTMF
ACK
COMMAND OPERATION
TERMI-
NATOR
DTMF
ACK
DEFAULT
43#
Bi
Test Call: DDHHMM
DD:00-07=0-7 Day(s)
HH= 00-23=0-23 Hour(s)
MM=00-59=0-59 Min(s)
000000= Disable
#
Bi
7 Days
44#
Bi
Mobility time
00= Disable, 01 - 36= 1 - 36 Hours
#
Bi
Mobility time
disable
46#
Bi
Two-Way Period,
01=1 min, 02=2mins, 03=3mins, 04=4mins,
05=5mins, 06=6mins, 07=7mins, 08=8mins,
09=9mins, 10=10mins.
#
Bi
10 minutes
47#
Bi
Off-set time, 1=1 hour, 2=2 hours, 3=3 hours,
4=4 hours, 5=8hours, 6=12 hours
#
Bi
1 Hour
49#
Bi
Supervision, 0 = disable, 1 = 4 days, 2 = 5 days, 3 =
6 days,4 = 7 days, 5 = 8 days, 6 = 9 days, 7 = 10 days
#
Bi
Disable
53#
Bi
Voice prompt language.
0=English,1=Arabic,2=Spanish,3=Russian,
19= other, 20=Beep only
#
Bi
0
54#
Bi
Fall Sensor Sensitivity
1 ~ 5 Levels
1= Lowest Sensitivity, 5= Highest Sensitivity
#
Bi
3
55#
Bi
High Temperature Reporting Threshold
032 ~ 200 °F
#
Bi
95 °F
56#
Bi
Low Temperature Reporting Threshold
032 ~ 200 °F
#
Bi
47 °F
57#
Bi
CO2 Alarm Reporting Threshold
0 - 9999ppm
#
Bi
800ppm
63#
Bi
Set Speaker Volume
Enter: Mode
*
+ Speaker Volume
Note: Mode Number: 1 digit (2:Two-way)
Speak volume: 1 digit (1-5 level) (4G/LTE)
#
Bi
Two way mode
Volume Level 5
64#
Bi
Set Microphone Sensitivity:
Note: Mic sensitivity: 1 digit (1-5 level)
Only can be adjusted in the two-way mode.
#
Bi
Two way Mode: 3
66#
Bi
Guard time delay for Fall Sensor, 00 = Instant
reporting; … 99 = 99 seconds
#
Bi
15 sec
76#
Bi
Call progress tone, 0 = Off, 1 = On
#
Bi
Off
77#
Bi
Speech report acknowledgement,
0 = Any DTMF On,
1 = OFF-HOOK
#
Bi
Any DTMF
80#
Bi
Remove all devices (learnt in Command 93-94)
---
---
---
81#
Bi
Remove Zone 1 device
---
---
---
82#
Bi
Remove Zone 2 device
93#
Bi
Learn-in silent emergency transmitters
---
Bi Bi
No device
94#
Bi
Learn-in smoke detectors, CO detectors,
pendants and fixed emergency transmitters, long
range pendants
---
Bi Bi
No device
98#
Bi
Load defaults when
**
is pressed (DTMF A is
heard after defaults have been loaded)
#
Bi
---
99#
Bi
Exit programming mode
---