background image

 

1

Water Leak Sensor (WLS-23-F1) 

 
Introduction 

WLS-23 is a Water Leak Sensor. It is capable of sending wireless signals to the Control Panel upon water 
detection. The  Water  Sensor  can  be  placed  on  the  ground,  or  mounted  on  the  wall  using  the  extension 
cable  to  detect  water  leakage  or  flood  condition.  The  Water  Sensing  Cable  and  built-in  water  sensing 
probes can detect water leakage or flood condition. It can be placed on the ground, or mounted on the wall 
and further extended by connecting to another water sensing cable to improve detection range. 

The Water Leak Sensor includes the following frequency models: 
433FM F1 
868FM F1 

 

Parts Identification

 

1.  Learn/Test Button aka LED Indicator 

LED Indication: 

-  Flashes 3 times:   

The Water Sensor is transmitting a signal. 

-  Flashes 6 times:   

The Water Sensor is transmitting an alarm/restore signal. 

Learn/Test button usage: 

-  Press the “LEARN” button once to send a learning signal to the 

Control Panel.   

2.  Buzzer 

3.  External Water Probe Connector 

4.  Battery Compartment 

-  The Water Leak Sensor is powered by one CR123 3V Lithium 

battery. 

5.  Mounting Hook 

6.  Function Button (inside the cover) 

7.  Built-in water sensing probes 

8.  Waterproof Case 

9.  Battery Insulator 

10.  Learn (characters imprinted on the back cover)   

-  Press once to send a temperature/humidity and supervisory 

signal to the coordinator.

 

 

-  Press and hold the button for 10 seconds to reset the Water 

Sensor. 

-  Press once during alarm to enter Alarm Silenced Mode. 

 

Features 

 

Water Detection 

   

 

The Water Sensor will be activated when water is detected through: 
1.  The 

external water sensing cable

Please  remove  the  pre-installed  plastic  plug  from  the  external  water  probe  connector,  the 
Water  Sensor  will  emit  beep  sound  every  10  seconds  to  indicate  absence  of  plastic  plug, 
please connect the external water probe to the connector (Refer to 

Mounting

 for details). 

2.  The 

built-in water sensing probe

Please make sure the plastic plug is well inserted when using this type of detection function. 
(Refer to 

Mounting

 for details). 

 

If water is detected through the above two detecting methods, the Water Sensor will start alarming 
and will transmit an alarm signal to the Control Panel. 

 

If water persists, the Water Sensor will continue alarming and send alarm signal every 2 minutes. 

 

If water is subsided, the Water Sensor will stop alarming and transmit a restore signal. 
 

Содержание WLS-23-F1

Страница 1: ... 5 Mounting Hook 6 Function Button inside the cover 7 Built in water sensing probes 8 Waterproof Case 9 Battery Insulator 10 Learn characters imprinted on the back cover Press once to send a temperature humidity and supervisory signal to the coordinator Press and hold the button for 10 seconds to reset the Water Sensor Press once during alarm to enter Alarm Silenced Mode Features Water Detection T...

Страница 2: ...ting Started Remove the battery insulator to power on the Water Sensor Put your Control Panel into learning mode Please refer to your Control Panel manual for details Press the Learn Test button once to transmit a learn code to the Control Panel the LED will flash 3 times to indicate If the Control Panel receives the learn code it will display the information accordingly refer to the Control Panel...

Страница 3: ...ontrol Panel Upon receiving an alert notification from the Control Panel unplug the Water Sensing Cable Use a towel to dry the Water Sensing Cable It is recommended to air dry residual water in a ventilated place for at least two hours before inserting the sensing cable NOTE Avoid direct or indirect sunshine Improper storage can cause damage to the sensor and the cable ...

Страница 4: ...15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation ...