Device Type:
Sensor
– Notification Smoke Alarm
Role Type: Listening Sleeping Slave (LSS)
Max Association Group:
2
Command Class Support/Control
Mandatory CC Support:
Z-Wave Plus Info CC
Association CC, (S2)
Multi Channel Association, (S2)
Association Group Information CC, (S2)
Transport Service CC
Version CC, (S2)
Manufacturer Specific CC, (S2)
Device Reset Locally CC, (S2)
Power Level CC, (S2)
Battery CC, (S2)
Security 2
Notification CC, (S2)
Sensor Multilevel CC, (S2)
Supervision CC, (S2)
Wake UP CC (SD-29)
Firmware Update Md CC, (S2)
Z
Z
-
-
W
W
a
a
v
v
e
e
’
’
s
s
G
G
r
r
o
o
u
u
p
p
s
s
(
(
A
A
s
s
s
s
o
o
c
c
i
i
a
a
t
t
i
i
o
o
n
n
C
C
o
o
m
m
m
m
a
a
n
n
d
d
C
C
l
l
a
a
s
s
s
s
V
V
e
e
r
r
s
s
i
i
o
o
n
n
2
2
)
)
The Smoke Detector can be set to send reports to associated Z-Wave devices. It supports 2 association groups.
Group 1 for “LifeLine”:
(maximum node: one)
Battery CC (COMMAND_CLASS_BATTERY)
Notification CC,V4 (COMMAND_CLASS_NOTIFICATION)
SensorMutilevel CC, V4 (COMMAND_CLASS_SENSOR_MULTILEVEL)
Device Reset Locally CC (COMMAND_CLASS_DEVICE_RESET_LOCALLY)
Group 2 for “Smoke Basic set”:
(maximum node: one)
Basic CC (COMMAND_CLASS_BASIC)
When the Smoke Detector is active, it will send Basic Set (0xFF) in Group 2.
When the Smoke Detector is restored, it will send Basic Set (0x00) in Group 2.
C
C
o
o
m
m
m
m
a
a
n
n
d
d
C
C
l
l
a
a
s
s
s
s
D
D
a
a
t
t
a
a
F
F
o
o
r
r
m
m
a
a
t
t
Battery: [COMMAND_CLASS_BATTERY] [BATTERY_REPORT]
0x64 --- 100% Battery Full
0x4B --- 75% Battery
0x32 --- 50% Battery
0x19 --- 25% Battery
0xFF --- Battery Dead (Cut Off)
Smoke Detection Triggered/Smoke Detection Restored: [COMMAND_CLASS_NOTIFICATION] [NOTIFICATION_REPORT]
Smoke Alarm Triggered:
00 00 00 FF
01 02
00
Smoke Alarm Restored:
00 00 00 FF
01 00 01 02
Smoke Alarm Silenced:
00 00 00 FF
01 06 00
Heat Detection Triggered/Heat Detection Restored: [COMMAND_CLASS_NOTIFICATION] [NOTIFICATION_REPORT]
Heat Alarm Triggered:
00 00 00 FF
04 02
00
Heat Alarm Restored:
00 00 00 FF
04 00 01 02
Heat Alarm Silenced:
00 00 00 FF
04 09 00
Movement Detection Triggered/Movement Detection Restored: [COMMAND_CLASS_NOTIFICATION]
[NOTIFICATION_REPORT]
Movement Detection Triggered: 00 00 00 FF
07 08
00
Movement Detection Restored: 00 00 00 FF
07 00 01 08
Tamper Open/Close report [COMMAND_CLASS_NOTIFICATION] [NOTIFICATION_REPORT]
The SD-29 is protected by a tamper switch which is compressed when the SD-29 is hooked onto the mounting bracket. When
the SD-29 is removed from the mounting bracket, the tamper switch will be activated and the SD-29 will send a tamper open
signal to the system control panel to remind the user of this condition.
Tamper Open :
00 00 00
07 03
00 00
Tamper Close:
00 00 00
07 00 01 03