Walk Test 

To test whether the Power Switch is able to communicate with the Control Panel: 

Put the Control Panel into Walk Test mode.

Press the Test Button on the Power Switch.

The Control Panel should display if the Power Switch is within the operation range (please refer

to the operation manual of the Control Panel).

Supervision 

After  the  Power  Switch  is  successfully  learned  in  to  the  Control  Panel,  the  device  will  automatically
transmit supervisory signal along with ON/Off status to the Control Panel at random intervals of 30 to 50 
minutes. 

If the Control Panel has not received the signal from the Power Switch for the preset period of time, the
Control Panel will indicate on its display that the particular Power Switch is experiencing an out-of-signal 
problem. 

Operation

 

Installation

Plug the Power Switch into a power outlet, then

 

plug the appliance into the socket of the Power Switch.

The appliance must be in ON status.

Appliance Control

After the Power Switch is successfully learned in to the Control Panel, the Control Panel can remotely
turn  on/off  the  Power  Switch  to  control  the  appliance.  Please  refer  to  your  Control  Panel  manual  for
details.

You can also press the button on the Power Switch to toggle its on/off status

If the Power Switch is removed from power outlet, after re-plugging the Power Switch, its previous on/off
status and current energy output data (PSM-29-F1 only) will be transmitted to the Control Panel.

Energy Consumption Monitor (For PSM-29-F1 Only)

With  a  built-in  power  meter  to  measure  electricity  consumption,  the  PSM-29-F1  Power  Meter  Switch  will 
transmit power consumption data to the Control Panel when: 

When the Power Meter Switch is turned On/Off.

Whenever the Power Switch energy output changes by +/- 2W.

Whenever accumulated power usage increases by 0.2kW/hr.

Maximum Operation Load

For 110V: the maximum operation load is 1760W and 16A.

For 230V: the maximum operation load is 3680W and 16A.

If  the  Power  Switch  is  overheating,  it  will  cut  off  power  automatically  as  a  safety  measure.  The  LED
indicator will flash quickly. The Power Switch must be unplugged and re-plugged after cut off to resume
normal operation.

Factory Reset 

Factory resetting the Power Switch will clear its memory and restore it to factory default settings.

Press and hold the test button while powering on the Power Switch, then release the button when the
LED lights up to factory reset.