battery compartment. The battery compartment has a strip which should be pressed under the battery when battery is inserted. 
When removing battery, simply lift the strip. 
The PIR features Low Battery Detection function. When the battery voltage is low, the PIR will transmit Low Battery signal to 
the Control Panel. If movement is detected under Low Battery condition, the LED Indicator will flash to indicate. 
If  battery  is  not  changed  after  Low  Battery  and  is  exhausted,  the  LED  will  flash  every  2  seconds  and  the  PIR  will  stop  all 
operation. 
When changing battery, after removing the old battery, press the Function Button twice to fully discharge before inserting new 
battery. 
 

 

Supervision 

The  PIR  will  transmit  a  supervision  signal  along  with  the  reading  signal  to  report  its  condition  regularly.  The  factory  default 
interval is 30 minutes. 

 

Test Mode 

 

Test mode is for you to check the PIR’s detection range. 

 

To enter Test mode, press the Test button once enter the Test mode for 3 minutes. 

 

During Test Mode, you can trigger PIR sensor to check its detection coverage. If PIR is triggered, the LED will light up to 
indicate. 

 

Temperature and Humidity Detection 

   

 

The  sensor  measures  temperature  and  humidity  to  transmit  measured  data  to 

the  Control  Panel

  regularly.  The  factory 

default interval is 30 minutes. 

 

When the temperature changes by +/- 2

˚

C, the PIR will transmit a signal. 

 

When the humidity c/- 10%, the PIR will transmit a signal. 

 

You can also press the Test Button once to transmit a temperature/humidity signal manually. 

 

Light Monitoring

 

 

PIR  models  with  built-in  ambient  light  sensor  measures  illuminance  and  transmits  measured  data  to 

the  Control  Panel

 

regularly. The factory default interval is 30 minutes. 

 

When the current illuminance changes by +/- 10%, the PIR will also transmit a signal. 

 

You can also press the Test Button once to transmit current lux reading manually. 

 
Getting Started 

 

Pull out the battery insulator to activate battery. 

 

Put the Control Panel into learning mode; refer to Control Panel manual for details. 

 

Press the test button on the PIR. 

 

Refer to Control Panel manual to complete the learn-in process. 

 

After the PIR is learnt-in, put the Control Panel into “Walk Test” mode, hold the PIR in the desired location, and press the 
Test button to confirm this location is within signal range of the Control Panel, refer to Control Panel manual to complete 
Walk Test. 

               

When you are satisfied that the PIR works in the chosen location, you can proceed to mounting. 

 
 

Installation 

 

Mounting Height and PIR Detection Coverage 

 

The PIR has detection coverage of a 120

cone to the front. When mounted at 1.2m to 2.1m height and facing forward, the 

PIR has maximum range of 10 meters. 

 

The PIR direction can be changed by simply rotating the PIR on the base. After changing direction, make sure to test the 
detection function to confirm the new detection coverage. 

 

Assembly 

 

The PIR is comprised of a front cover and a back cover. The back cover must be separated for battery installation and 
learn-in process. 

 

To separate the back cover, hold the PIR in both hands and turn according to picture below to open the PIR. 

 

 

Installation 

 

The  PIR  main  body  has  internal  magnet  at  bottom  and  back,  which  attaches  the  main  body  to  PIR  magnet  base  when 